W DOC AIRBUS | AMM A320F

Operational Test of the Extract and Blower Fans (without the CFDS)


TASK 21-26-51-710-001-A
Operational Test of the Extract and Blower Fans (without the CFDS)


FIN: 18HQ
FIN: 20HQ
1. Reason for the Job
To do the test after the removal/installation of the blower fan or the extract fan if the CFDS is unserviceable.
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 21-26-51-865-053-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAE02
** ON A/C ALL
123VUAVNCS VENT/BLOWER/FAN1HQAD10
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAC04
Subtask 21-26-51-869-052-A
B. Make sure that the throttle control levers of the engines 1 and 2 are at idle.
Subtask 21-26-51-861-052-A
C. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-51-860-051-A
D. Aircraft Maintenance Configuration
   (1) On the VENTILATION section of the panel 22VU:
  • make sure that the BLOWER and EXTRACT pushbutton switches are in the AUTO configuration (pushed with the FAULT and OVRD legends off).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure
Subtask 21-26-51-710-050-A
A. Operational Test of the Extract and Blower Fans
ACTION
RESULT
1.On the circuit breaker panel 122VU:
  • open the circuit breaker 3HQ.
On the VENTILATION section of the panel 22VU:
  • the FAULT legends of the BLOWER and EXTRACT pushbutton switches come on. On the upper ECAM DU:
  • the AVNCS SYS FAULT indication comes into view after approximately 10 seconds.
2.On the circuit breaker panel 122VU:
  • close the circuit breaker 3HQ.
On the VENTILATION section of the panel 22VU:
  • the FAULT legends of the BLOWER and EXTRACT pushbutton switches go off after 10 seconds. On the upper ECAM DU:
  • the AVNCS SYS FAULT indication goes out of view.
5. Close-up
Subtask 21-26-51-860-052-A
A. Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
Subtask 21-26-51-862-052-A
B. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:47:58 UTC