Removal of the Extract and Blower Fans
TASK 21-26-51-000-001-A
Removal of the Extract and Blower Fans
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-51-020-050-B
[Rev.10 from 2021]
2026.04.02 06:11:07 UTC
Removal of the Extract and Blower Fans
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
CAUTION:
USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
Subtask 21-26-51-861-050-A Subtask 21-26-51-865-050-A B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-51-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 18HQ (FANEXTRACT, AVNCS VENT) | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
| ** ON A/C ALL | |||
| FOR FIN: 20HQ (FANBLOWER, AVNCS VENT) | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
Subtask 21-26-51-020-050-B
A. Removal of the Extract and Blower Fans
(1) Disconnect the electrical connector (4) from the fan (5).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the clamps (7) and (9).
(5) Remove the clamp (2).
(6) Hold the fan (5), open the clamps (6) and remove the fan (5).
(7) Remove and discard the O-ring (3).
(8) Remove the flexible sleeve (8).
(9) Put the PLUG-BLANKING in each disconnected line end.
(1) Disconnect the electrical connector (4) from the fan (5).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the clamps (7) and (9).
NOTE: Do not discard the clamps (7) and (9). You must keep and use them during the installation procedure.
(4) Move the flexible sleeve (8) on the pipe (10) to release the fan (5). (5) Remove the clamp (2).
(6) Hold the fan (5), open the clamps (6) and remove the fan (5).
(7) Remove and discard the O-ring (3).
(8) Remove the flexible sleeve (8).
(9) Put the PLUG-BLANKING in each disconnected line end.
Extract Fan