Removal of the Skin Heat Exchanger
TASK 21-26-45-000-001-A
Removal of the Skin Heat Exchanger
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-45-861-050-A Subtask 21-26-45-865-050-A
Subtask 21-26-45-020-050-A
[Rev.10 from 2021]
2026.04.02 06:11:06 UTC
Removal of the Skin Heat Exchanger
CAUTION:
USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-31-41-000-001-A | Removal of the Forward Galley Unit |
| TASK 25-41-41-000-001-A | Removal of Lavatory A |
| TASK 25-41-41-000-001-B | Removal of Lavatory A |
| TASK 25-80-00-000-001-A | Removal of the Insulation Blankets |
Subtask 21-26-45-861-050-A Subtask 21-26-45-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-45-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
Subtask 21-26-45-020-050-A
A. Removal of the Skin Heat Exchanger
(1) Remove the lavatory A, if install (Ref. AMM TASK 25-41-41-000-001).
(2) Remove the galley unit at location 1, if install (Ref. AMM TASK 25-31-41-000-001).
(3) Remove all the insulation blankets between FR12 and FR14 above and below the floor panels (Ref. AMM TASK 25-80-00-000-001).
(4) Remove the skin heat exchanger:
(a) Remove the screws (1).
(b) Remove the washers (2).
(c) Remove the panels (3) of the skin heat exchanger.
(1) Remove the lavatory A, if install (Ref. AMM TASK 25-41-41-000-001).
(2) Remove the galley unit at location 1, if install (Ref. AMM TASK 25-31-41-000-001).
(3) Remove all the insulation blankets between FR12 and FR14 above and below the floor panels (Ref. AMM TASK 25-80-00-000-001).
(4) Remove the skin heat exchanger:
(a) Remove the screws (1).
(b) Remove the washers (2).
(c) Remove the panels (3) of the skin heat exchanger.
Skin Heat Exchanger