Operational Check of NRV for Free Movement
TASK 21-26-43-710-001-A
Operational Check of NRV for Free Movement
Refer to the MPD TASK: 212643-09
OPERATIONAL CHECK OF NRV FOR FREE MOVEMENT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-43-865-087-A ** ON A/C NOT FOR ALL
Subtask 21-26-43-710-054-A ** ON A/C NOT FOR ALL
Subtask 21-26-43-410-092-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:06 UTC
Operational Check of NRV for Free Movement
ZONE: 120
1. Reason for the JobRefer to the MPD TASK: 212643-09
OPERATIONAL CHECK OF NRV FOR FREE MOVEMENT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-26-43-100-001-A | Inspection of the Siphon Assembly (Strainer) for Cleanliness |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 21-26-43-865-087-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-26-43-941-067-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
B. Safety Precautions
(1) Make sure that the throttle control levers of the engines 1 and 2 are at idle.
Subtask 21-26-43-010-099-A ** ON A/C NOT FOR ALL (1) Make sure that the throttle control levers of the engines 1 and 2 are at idle.
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 21-26-43-861-086-A ** ON A/C NOT FOR ALL Subtask 21-26-43-860-055-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
E. Aircraft Maintenance Configuration
(1) On the VENTILATION section of the panel 22VU:
4. Procedure(1) On the VENTILATION section of the panel 22VU:
- make sure that the BLOWER and EXTRACT pushbutton switches are in the AUTO configuration (pushed and with the FAULT and OVRD legends off).
Subtask 21-26-43-710-054-A ** ON A/C NOT FOR ALL
A. Operational Test of the Check Valve of the Syphon Assembly
(a) If there are debris, clean the syphon assembly (Ref. AMM TASK 21-26-43-100-001).
(2) Make sure that the ball of the check valve moves up.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 21-26-43-861-090-A ** ON A/C NOT FOR ALL NOTE: The energization of the aircraft electrical circuits starts a full test of the ventilation system. The test continues for 2 minutes approximately.
(1) Make sure that the bowl of the syphon is clean. (a) If there are debris, clean the syphon assembly (Ref. AMM TASK 21-26-43-100-001).
(2) Make sure that the ball of the check valve moves up.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
B. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001)
(1) Make sure that the ball of the check valve moves down.
5. Close-up(Ref. AMM TASK 24-42-00-861-001)
(1) Make sure that the ball of the check valve moves down.
Subtask 21-26-43-410-092-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 21-26-43-862-086-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Check Valve of the Avionics Ventillation Water / Dust Separation