W DOC AIRBUS | AMM A320F

Servicing of the Filter Cartridge


TASK 21-26-43-600-019-A
Servicing of the Filter Cartridge


WARNING: PUT ON GLOVES, A COVERALL WITH A HOOD, GOGGLES AND A PARTICULATE RESPIRATOR BEFORE YOU TOUCH THE FILTER. THE FILTER REMOVES SMALL PARTICLES (SMOKE, DUST, LINT, FIBERS, POLLEN) AND INFECTIOUS MATERIALS (BACTERIA, VIRUSES, MOLD SPORES, FUNGI) FROM THE AIR. THESE MATERIALS CAN CAUSE ILLNESS.
WARNING: DO NOT LET THE FILTER TOUCH YOUR SKIN. DO NOT SHAKE OR HIT THE FILTER. DO NOT LET THE FILTER FALL. DO NOT USE COMPRESSED AIR TO CLEAN THE FILTER OR FILTER HOUSING. THIS CAN CAUSE THE INFECTIOUS MATERIAL TO BECOME AIRBORNE. DISCARD THE FILTER IN A PLASTIC DISPOSAL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, INFECTIOUS MATERIAL FROM THE FILTER CAN CAUSE ILLNESS.
WARNING: DO NOT LET THE FILTER TOUCH YOUR SKIN. DO NOT SHAKE OR HIT THE FILTER. DO NOT LET THE FILTER FALL. DO NOT USE COMPRESSED AIR TO CLEAN THE FILTER OR FILTER HOUSING. THIS CAN CAUSE THE INFECTIOUS MATERIAL TO BECOME AIRBORNE. DISCARD THE FILTER IN A PLASTIC DISPOSAL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, INFECTIOUS MATERIAL FROM THE FILTER CAN CAUSE ILLNESS.
CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
F Filter Cartridge ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 21-26-43-862-111-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 21-26-43-861-116-A ** ON A/C NOT FOR ALL
B. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
Subtask 21-26-43-865-119-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
123VUAVNCS VENT/EXTC/FAN2HQAC04
123VUAVNCS VENT/BLOWER/FAN1HQAD10
Subtask 21-26-43-010-094-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
   (2) Open the access door 824.
4. Procedure
Subtask 21-26-43-020-081-A ** ON A/C NOT FOR ALL
A. Removal of the Filter Cartridge
   (1) Release each of the four fasteners:
     (a) Move the lock (14) to the door of the body (10).
     (b) Lift the fasteners.
   (2) Push the door and lift the fasteners to fully release the door of the body (10).
   (3) Open the door of the body (10).
   (4) Hold the two ends of the ring (12) with the loop bowden cable.
   (5) Pull the filter (13) with the straps to disengage the bearing from its housing.
   (6) Remove the filter (13) from the body (10).
   (7) Bend the end of the ring (12) and remove it.
Subtask 21-26-43-615-068-A ** ON A/C NOT FOR ALL
B. Send the Filter Cartridge in Shop for Cleaning.
Subtask 21-26-43-160-073-A ** ON A/C NOT FOR ALL
C. Clean the component interface and/or the adjacent area.
Subtask 21-26-43-210-081-A ** ON A/C NOT FOR ALL
D. Do an inspection of the component interfaces and the adjacent area.
Subtask 21-26-43-420-082-A ** ON A/C NOT FOR ALL
E. Installation of the Filter Cartridge
   (1) Move apart the two ends of the ring (12) to install it into the groove of the filter (13).
   (2) Hold the two ends of the ring with the bowden cable.
   (3) Put the assembly through the door into the body (10) and engage the bearing of the filter (13) into the housing.
   (4) Release the ring (12), close the door and lock the four elastic-fastener devices.
5. Close-up
Subtask 21-26-43-410-089-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
   (3) Remove the access platform(s).
Subtask 21-26-43-865-120-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
123VUAVNCS VENT/EXTC/FAN2HQAC04
123VUAVNCS VENT/BLOWER/FAN1HQAD10
Subtask 21-26-43-861-117-A ** ON A/C NOT FOR ALL
C. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
[Rev.10 from 2021] 2026.03.31 23:03:14 UTC