Removal of the Filter Assembly
TASK 21-26-43-000-007-A
Removal of the Filter Assembly
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-43-862-115-A ** ON A/C NOT FOR ALL Subtask 21-26-43-861-120-A ** ON A/C NOT FOR ALL Subtask 21-26-43-865-131-A ** ON A/C NOT FOR ALL
Subtask 21-26-43-020-084-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:11:06 UTC
Removal of the Filter Assembly
WARNING:
PUT ON GLOVES, A COVERALL WITH A HOOD, GOGGLES AND A PARTICULATE RESPIRATOR BEFORE YOU TOUCH THE FILTER. THE FILTER REMOVES SMALL PARTICLES (SMOKE, DUST, LINT, FIBERS, POLLEN) AND INFECTIOUS MATERIALS (BACTERIA, VIRUSES, MOLD SPORES, FUNGI) FROM THE AIR. THESE MATERIALS CAN CAUSE ILLNESS.
WARNING:
DO NOT LET THE FILTER TOUCH YOUR SKIN. DO NOT SHAKE OR HIT THE FILTER. DO NOT LET THE FILTER FALL. DO NOT USE COMPRESSED AIR TO CLEAN THE FILTER OR FILTER HOUSING. THIS CAN CAUSE THE INFECTIOUS MATERIAL TO BECOME AIRBORNE. DISCARD THE FILTER IN A PLASTIC DISPOSAL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, INFECTIOUS MATERIAL FROM THE FILTER CAN CAUSE ILLNESS.
WARNING:
PUT ALL AIR FILTERS THAT YOU REMOVE FROM THE AIRCRAFT INTO PLASTIC DISPOSAL BAGS. AIR FILTERS CAN CONTAIN INFECTIOUS MATERIALS WHICH CAN CAUSE ILLNESS. OBEY AIRLINE POLICY AND LOCAL HEALTH DEPARTMENT AND LAW ENFORCEMENT REGULATIONS FOR DISPOSAL OF INFECTIOUS MATERIALS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-26-43-600-018-A | Servicing of the Demister Filter |
| TASK 21-26-43-600-019-A | Servicing of the Filter Cartridge |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 21-26-43-862-115-A ** ON A/C NOT FOR ALL Subtask 21-26-43-861-120-A ** ON A/C NOT FOR ALL Subtask 21-26-43-865-131-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-43-010-097-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
D. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the avionics-compartment aft door 824.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the avionics-compartment aft door 824.
(2) Open the access door 824.
Subtask 21-26-43-020-084-A ** ON A/C NOT FOR ALL
A. Removal of the Demister Filter and Filter Cartridge
(1) Remove the demister filter (Ref. AMM TASK 21-26-43-600-018).
(2) Remove the filter cartridge (Ref. AMM TASK 21-26-43-600-019).
Subtask 21-26-43-910-055-A ** ON A/C NOT FOR ALL (1) Remove the demister filter (Ref. AMM TASK 21-26-43-600-018).
(2) Remove the filter cartridge (Ref. AMM TASK 21-26-43-600-019).
NOTE: Close the door and lock the four elastic-fastener devices for the removal of the body.
B. The body filter weighs approximately 4.6 kg (10.14 lb). Make sure that you support it correctly.
Subtask 21-26-43-020-085-A ** ON A/C NOT FOR ALL C. Removal of the Filter Assembly
(1) Remove the clamps (1).
(2) Move the flexible sleeve (14) on the duct (15) to disengage the filter body (4).
(3) Remove the clamp (9).
(4) Release the drain hose (8).
(5) Remove the nuts (7) and screws (10) while you hold the equipped flange (12).
(6) Remove the nuts (5) and the screws (2).
(7) Remove the filter body (4).
(8) Remove the seal (11) and discard it.
(9) Put PLUG - BLANKING on the disconnected line ends.
(1) Remove the clamps (1).
(2) Move the flexible sleeve (14) on the duct (15) to disengage the filter body (4).
(3) Remove the clamp (9).
(4) Release the drain hose (8).
(5) Remove the nuts (7) and screws (10) while you hold the equipped flange (12).
(6) Remove the nuts (5) and the screws (2).
(7) Remove the filter body (4).
(8) Remove the seal (11) and discard it.
(9) Put PLUG - BLANKING on the disconnected line ends.
Filter Assembly (2081HM, 2082HM, 2083HM)