W DOC AIRBUS | AMM A320F

Removal of the Avionics Equipment Ventilation Computer (AEVC)


TASK 21-26-34-000-001-A
Removal of the Avionics Equipment Ventilation Computer (AEVC)


ZONE: 128
FIN: 10HQ
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
128
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
3. Job Set-up
Subtask 21-26-34-861-050-A
A. Energize the ground service network
CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
   (1) Energize the ground service network from the external power (Ref. AMM TASK 24-42-00-861-001).
Subtask 21-26-34-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-34-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
   (2) Open the access door 824.
4. Procedure
Subtask 21-26-34-020-051-A
A. Removal of the AEVC
   (1) Loosen the nut (4).
   (2) Lower the nut (4).
   (3) Pull the AEVC (1) on its rack (3) to disconnect the electrical connector (2).
   (4) Remove the AEVC (1) from its rack (3).
   (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
[Rev.10 from 2021] 2026.04.02 06:11:03 UTC