Operational Test of the Skin Temperature Sensor (without the CFDS)
TASK 21-26-13-710-001-A
Operational Test of the Skin Temperature Sensor (without the CFDS)
To do the test after the removal/installation of the skin temperature sensor 28HQ if the CFDS is unserviceable.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-13-865-053-A
Subtask 21-26-13-710-051-A
Subtask 21-26-13-410-051-A Subtask 21-26-13-860-051-A Subtask 21-26-13-862-052-A
[Rev.10 from 2021]
2026.04.02 06:47:57 UTC
Operational Test of the Skin Temperature Sensor (without the CFDS)
FIN: 28HQ
1. Reason for the JobTo do the test after the removal/installation of the skin temperature sensor 28HQ if the CFDS is unserviceable.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 21-26-13-865-053-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-26-13-869-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C ALL | |||
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
B. Make sure that the throttle control levers of the engines 1 and 2 are at idle.
Subtask 21-26-13-861-052-A Subtask 21-26-13-869-053-A D. On the VENTILATION section of the panel 22VU:
Subtask 21-26-13-860-052-A - make sure that the BLOWER and EXTRACT pushbutton switches are in the AUTO configuration (pushed with the FAULT and OVRD legends off).
E. Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 21-26-13-010-051-A (Ref. AMM TASK 31-60-00-860-001).
F. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822.
(2) Open the access door 822.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822.
(2) Open the access door 822.
Subtask 21-26-13-710-051-A
A. Operational Test of the Skin Temperature Sensor (28HQ)
5. Close-up| ACTION | RESULT |
|---|---|
1.In the lateral avionics compartment:
| The flight configuration is simulated for the ventilation system. On the aircraft skin, make sure that:
|
| 2.Connect the connector 28HQ-A to the skin temperature sensor 28HQ. | No change. |
3.On the rear circuit breaker panel 122VU:
| NOTE: This starts a full test of the ventilation system. |
| 4.Wait until the end of the test | On the aircraft skin, make sure that:
|
Subtask 21-26-13-410-051-A Subtask 21-26-13-860-051-A Subtask 21-26-13-862-052-A