Removal of the Avionics-Ventilation Comfort Duct-Temperature-Sensor
TASK 21-26-12-000-802-A
Removal of the Avionics-Ventilation Comfort Duct-Temperature-Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-12-020-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:02:36 UTC
Removal of the Avionics-Ventilation Comfort Duct-Temperature-Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
CAUTION:
USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
Subtask 21-26-12-861-055-A ** ON A/C NOT FOR ALL Subtask 21-26-12-865-062-A ** ON A/C NOT FOR ALL B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-12-010-058-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824.
(2) Open access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824.
(2) Open access door 824.
Subtask 21-26-12-020-055-A ** ON A/C NOT FOR ALL
A. Removal of the Duct Temperature Sensor
(1) Disconnect the electrical connector (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Removal of the lockwire
(4) Remove the sensor (2) and discard the O-ring (3).
(1) Disconnect the electrical connector (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Removal of the lockwire
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Cut and discard the lockwire. (4) Remove the sensor (2) and discard the O-ring (3).
Avionics-Ventilation Comfort Duct-Temperature-Sensor