Removal of the Avionics Ventilation Duct Temperature Sensors
TASK 21-26-12-000-001-B
Removal of the Avionics Ventilation Duct Temperature Sensors
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-12-861-052-A ** ON A/C NOT FOR ALL Subtask 21-26-12-865-053-A ** ON A/C NOT FOR ALL
Subtask 21-26-12-020-052-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.02 06:11:02 UTC
Removal of the Avionics Ventilation Duct Temperature Sensors
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 21-26-12-861-052-A ** ON A/C NOT FOR ALL Subtask 21-26-12-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-12-010-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
Subtask 21-26-12-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Duct Temperature Sensors
(1) Disconnect the electrical connectors (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Cut and discard the lockwire.
(4) Remove the sensors (2) and discard the O-rings (3).
(1) Disconnect the electrical connectors (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Cut and discard the lockwire.
(4) Remove the sensors (2) and discard the O-rings (3).
Duct Temperature Sensors