Operational Check of Ditching Configuration Control Circuit
TASK 21-26-00-710-004-A
Operational Check of Ditching Configuration Control Circuit
Refer to the MPD TASK: 212600-04
OPERATIONAL CHECK OF DITCHING CONFIGURATION CONTROL CIRCUIT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-00-040-084-A ** ON A/C NOT FOR ALL
Subtask 21-26-00-710-053-C
Subtask 21-26-00-410-050-A
[Rev.10 from 2021]
2026.04.02 06:11:01 UTC
Operational Check of Ditching Configuration Control Circuit
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 212600-04
OPERATIONAL CHECK OF DITCHING CONFIGURATION CONTROL CIRCUIT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-26-12-000-802-A | Removal of the Avionics-Ventilation Comfort Duct-Temperature-Sensor |
| TASK 21-26-12-400-802-A | Installation of the Avionics-Ventilation Comfort Duct-Temperature-Sensor |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TSM 21 | (for corrective action) |
Subtask 21-26-00-040-084-A ** ON A/C NOT FOR ALL
A. Deactivation of the Avionics-Ventilation Comfort Duct-Temperature-Sensor
(1) Disconnect the electrical connector from the avionics-ventilation comfort duct-temperature-sensor (Ref. AMM TASK 21-26-12-000-802).
Subtask 21-26-00-865-053-A (1) Disconnect the electrical connector from the avionics-ventilation comfort duct-temperature-sensor (Ref. AMM TASK 21-26-12-000-802).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-26-00-865-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C ALL | |||
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-00-941-089-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/CAB/PRESS/CTL1 | 1HL | D09 |
| 122VU | AIR COND/CAB PRESS/CTL/MAN | 3HL | Y23 |
| 122VU | AIR COND/CAB PRESS/CTL/2 | 2HL | Y22 |
D. Safety Precautions
(1) Make sure that the air conditioning packs are off.
(2) Make sure that the engine 1 and 2 throttle control levers are at idle.
Subtask 21-26-00-861-053-A (1) Make sure that the air conditioning packs are off.
(2) Make sure that the engine 1 and 2 throttle control levers are at idle.
E. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-00-860-058-C ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002).
NOTE: The energization of the aircraft electrical circuits starts a full test of the ventilation system. The test continues for 2 minutes approximately.
F. Aircraft Maintenance Configuration
(1) On the VENTILATION section of panel 22VU:
(3) On the ECAM control panel, push the PRESS pushbutton key.
(4) On the lower ECAM display unit:
Subtask 21-26-00-860-058-E ** ON A/C NOT FOR ALL (1) On the VENTILATION section of panel 22VU:
- Make sure that the BLOWER and EXTRACT pushbutton switches are in the AUTO configuration (the pusbutton switches are pushed and the FAULT and the OVRD legends are off).
(3) On the ECAM control panel, push the PRESS pushbutton key.
(4) On the lower ECAM display unit:
- The CAB PRESS page comes into view and shows the skin air-inlet (INLET) and the skin air-outlet (OUTLET) valves in the open position (if the outside air temperature is more than or equal to 12 DEG.C (53.6 DEG.F)).
NOTE: If the outside air temperature is less than 9 DEG.C (48.2 DEG.F), the skin air-inlet and the skin air-outlet valves are closed.
NOTE: If the avionics duct temperature is less than 40 DEG.C (104 DEG.F), the skin air-inlet and the skin air-outlet valves are closed.
F. Aircraft Maintenance Configuration
(1) On the VENTILATION section of panel 22VU:
(3) On the ECAM control panel, push the PRESS pushbutton switch.
(4) On the lower ECAM display unit:
Subtask 21-26-00-010-050-A (1) On the VENTILATION section of panel 22VU:
- Make sure that the BLOWER and EXTRACT pushbutton switches are in the AUTO configuration (the pusbutton switches are pushed and the FAULT and the OVRD legends are off).
(3) On the ECAM control panel, push the PRESS pushbutton switch.
(4) On the lower ECAM display unit:
- The CAB PRESS page comes into view and shows the skin air-inlet and the skin air-outlet valves in the open position, if the outside air temperature is more than or equal to 12 DEG.C (53.6 DEG.F).
NOTE: If the outside air temperature is less than 9 DEG.C (48.2 DEG.F), the skin air-inlet and the skin air-outlet valves are closed.
NOTE: If the avionics duct temperature is less than 40 DEG.C (104 DEG.F), the skin air-inlet and the skin air-outlet valves are closed.
G. Get Access
(1) Open access door 822 (Ref. AMM TASK 52-41-00-010-002).
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure(1) Open access door 822 (Ref. AMM TASK 52-41-00-010-002).
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 21-26-00-710-053-C
A. Operational Test of the Control Circuit of the Ditching Configuration
5. Close-upNOTE: You cannot do the operational test of the control circuit of the ditching configuration:
- If the external air temperature is less than 9 DEG.C (48.2 DEG.F), the skin air-inlet and the skin air-outlet valves are closed.
- If the avionics duct temperature is less than 40 DEG.C (104 DEG.F), the skin air-inlet and the skin air-outlet valves are closed.
| ACTION | RESULT |
|---|---|
1.On the CABIN PRESS section of panel 25VU:
| On the DITCHING pushbutton switch:
NOTE: If the VENT AVNCS SYS FAULT ECAM warning comes into view on the upper ECAM DU, open and close circuit breaker 3HQ. If the warning goes out of view, no more procedure is necessary. If the warning stays in view, do the troubleshooting procedure TSM 21. |
2.On the CABIN PRESS section of panel 25VU:
| On the DITCHING pushbutton switch:
|
Subtask 21-26-00-410-050-A
A. Close Access
(1) Close access door 822 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the access platform(s).
Subtask 21-26-00-860-059-A (1) Close access door 822 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the access platform(s).
B. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
Subtask 21-26-00-862-053-A Subtask 21-26-00-865-055-A (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-26-00-440-077-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/CAB/PRESS/CTL1 | 1HL | D09 |
| 122VU | AIR COND/CAB PRESS/CTL/MAN | 3HL | Y23 |
| 122VU | AIR COND/CAB PRESS/CTL/2 | 2HL | Y22 |
E. Reactivation of the Avionics-Ventilation Comfort Duct-Temperature-Sensor
(1) Connect the electrical connector to the avionics-ventilation comfort duct-temperature-sensor (Ref. AMM TASK 21-26-12-400-802).
(1) Connect the electrical connector to the avionics-ventilation comfort duct-temperature-sensor (Ref. AMM TASK 21-26-12-400-802).