1. Reason for the Job
MMEL 21-26-02
EXTRACT FAN (FAA ONLY)
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 21-26-00-861-106-A
Subtask 21-26-00-865-134-A
Subtask 21-26-00-942-095-A
[Rev.10 from 2021]
2026.04.02 06:10:57 UTC
Reactivation of the Extract Fan - FAA Operators Only
1. Reason for the Job
MMEL 21-26-02
EXTRACT FAN (FAA ONLY)
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-26-00-440-007-A | Reactivation of the Extract Fan |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-26-00-861-106-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-00-865-134-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-440-073-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
B. Reactivation of the Extract Fan - FAA Operators Only
(1) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
(3) In the cockpit, on the VENTILATION section of overhead panel 22VU:
(a) Make sure that the EXTRACT pushbutton switch is pushed (the OVRD legend is off).
5. Close-up(1) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
- 2HQ.
(3) In the cockpit, on the VENTILATION section of overhead panel 22VU:
(a) Make sure that the EXTRACT pushbutton switch is pushed (the OVRD legend is off).
Subtask 21-26-00-942-095-A
A. Aircraft Maintenance Configuration
(1) Remove the WARNING NOTICE(S).
Subtask 21-26-00-862-107-A (1) Remove the WARNING NOTICE(S).
B. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).