W DOC AIRBUS | AMM A320F

Reactivation of the Blower Fan - FAA Operators Only


TASK 21-26-00-440-803-A
Reactivation of the Blower Fan - FAA Operators Only


ZONE: 210
FIN: 20HQ
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NOYESNO0.50.51
1. Reason for the Job
MMEL 21-26-01
BLOWER FAN (FAA ONLY)
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 21-26-00-440-006-A
Reactivation of the Blower Fan
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 21-26-00-861-097-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure
Subtask 21-26-00-865-127-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
123VUAVNCS VENT/BLOWER/FAN1HQAD10
Subtask 21-26-00-440-070-A
B. Reactivation of the Blower Fan - FAA Operators Only
   (1) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
  • 1HQ.
   (2) Reactivate the blower fan (Ref. AMM TASK 21-26-00-440-006).
   (3) In the cockpit, on the VENTILATION section of overhead panel 22VU:
     (a) Make sure that the BLOWER pushbutton switch is pushed (the OVRD legend is off).
5. Close-up
Subtask 21-26-00-941-107-A
A. Aircraft Maintenance Configuration
   (1) Remove the WARNING NOTICE(S).
Subtask 21-26-00-862-100-A
B. Aircraft Maintenance Configuration
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:10:57 UTC