W DOC AIRBUS | AMM A320F

Reactivation of the Avionics Ventilation Filter


TASK 21-26-00-440-009-A
Reactivation of the Avionics Ventilation Filter


1. Reason for the Job
MMEL 21-26-09C
AVIONICS VENTILATION FILTER
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 21-26-00-861-079-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure
Subtask 21-26-00-440-059-A
A. On the VENTILATION part of the overhead control and indicating panel 22VU:
  • push the EXTRACT pushbutton switch (the OVRD legend goes off).
5. Close-up
Subtask 21-26-00-862-075-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:11:00 UTC