Reactivation of the Skin-Exchanger Isolation Valve
TASK 21-26-00-440-008-A
Reactivation of the Skin-Exchanger Isolation Valve
1. Reason for the Job
MMEL 21-26-06B
AVIONICS SKIN EXCHANGER ISOLATION VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-00-861-066-A Subtask 21-26-00-865-085-A
Subtask 21-26-00-440-060-A
Subtask 21-26-00-410-071-A
[Rev.10 from 2021]
2026.04.02 06:10:59 UTC
Reactivation of the Skin-Exchanger Isolation Valve
1. Reason for the Job
MMEL 21-26-06B
AVIONICS SKIN EXCHANGER ISOLATION VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-26-00-710-001-A | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| TASK 21-26-00-710-001-A-01 | Operational Check of the Avionics Equipment Ventilation (without the CFDS) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 21-26-00-861-066-A Subtask 21-26-00-865-085-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-26-00-010-070-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 822.
(2) Open access door 822 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 822.
(2) Open access door 822 (Ref. AMM TASK 52-41-00-010-002).
Subtask 21-26-00-440-060-A
A. Reactivation of the Skin Exchanger Isolation Valve
(1) Remove the tape and get the electric cable and its connector.
(2) Remove the blanking caps from the disconnected electrical connectors.
(3) Make sure that all the electrical connections are clean and in the correct condition.
(4) Connect the electrical connector to valve 24HQ.
Subtask 21-26-00-865-118-A (1) Remove the tape and get the electric cable and its connector.
(2) Remove the blanking caps from the disconnected electrical connectors.
(3) Make sure that all the electrical connections are clean and in the correct condition.
(4) Connect the electrical connector to valve 24HQ.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-26-00-710-061-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
C. Do an operational test of the ventilation system of the avionics equipment (Ref. AMM TASK 21-26-00-710-001).
5. Close-upSubtask 21-26-00-410-071-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 822 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 21-26-00-862-066-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 822 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Skin Exchanger Isolation Valve