W DOC AIRBUS | AMM A320F

Reactivation of the Extract Fan


TASK 21-26-00-440-007-A
Reactivation of the Extract Fan


1. Reason for the Job
MMEL 21-26-02B
AVIONICS EXTRACT FAN
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 21-26-00-869-109-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure
Subtask 21-26-00-440-056-A
A. Conditioned Air Inlet Valve
   (1) Make sure that the operation of avionics equipment ventilation with electrical ground power, has the time limits that follow:
  • outside air temperature 38 deg.C or less, no time limit
  • outside air temperature 45 deg.C, maximum of 3 hours
  • outside air temperature 55 deg.C, maximum of thirty five minutes.
   (2) On the VENTILATION section of the overhead control and indicating panel 22VU:
  • Push the EXTRACT pushbutton switch (the OVRD legend goes off).
5. Close-up
Subtask 21-26-00-941-095-A
A. Aircraft Maintenance Configuration
   (1) Remove the WARNING NOTICE(S).
Subtask 21-26-00-862-074-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).