ADIRU/AVNCS VENT Caution Light Inoperative
TASK 21-26-00-040-012-A
ADIRU/AVNCS VENT Caution Light Inoperative
1. Reason for the Job
MMEL 24-30-09A
EXTERNAL POWER PANEL ADIRU/AVNCS VENT CAUTION LIGHT (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 21-26-00-865-100-A
Subtask 21-26-00-710-069-A
Subtask 21-26-00-942-085-A
[Rev.10 from 2021]
2026.04.02 06:11:00 UTC
ADIRU/AVNCS VENT Caution Light Inoperative
1. Reason for the Job
MMEL 24-30-09A
EXTERNAL POWER PANEL ADIRU/AVNCS VENT CAUTION LIGHT (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-26-00-865-100-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-26-00-861-086-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C ALL | |||
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
B. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-00-860-066-A (Ref. AMM TASK 24-41-00-861-002).
NOTE: The energization of the aircraft electrical circuits starts a full test of the ventilation system. The test continues for 2 minutes approximately.
C. Aircraft Maintenance Configuration
(1) On the VENTILATION section of the panel 22VU:
4. Procedure(1) On the VENTILATION section of the panel 22VU:
- make sure that the BLOWER and the EXTRACT pushbutton switches are in the AUTO configuration (pushed, with the FAULT and OVRD legends off).
Subtask 21-26-00-710-069-A
A. Operational Test of the Mechanic Call Horn
5. Close-up| ACTION | RESULT |
|---|---|
1.On the circuit breaker panels 49VU and 122VU:
| On the CAPT and F/O glareshield panels 131VU and 130VU:
NOTE: The mechanic call horn operates only if engine 1 and engine 2 are stopped. NOTE: On the panel 108VU, push the RESET pushbutton switch to stop the mechanic call horn. |
2.On the circuit breaker panels 49VU and 122VU:
| |
Subtask 21-26-00-942-085-A
A. Safety Precautions
(1) Put WARNING NOTICE(S) in position in the cockpit to tell the crew that the ADIRU/AVNCS VENT caution light is inoperative.
(2) Make an entry in the logbook.
Subtask 21-26-00-862-088-A (1) Put WARNING NOTICE(S) in position in the cockpit to tell the crew that the ADIRU/AVNCS VENT caution light is inoperative.
(2) Make an entry in the logbook.
B. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).