ADIRU/AVNCS VENT Caution Light Inoperative


TASK 21-26-00-040-012-A
ADIRU/AVNCS VENT Caution Light Inoperative


1. Reason for the Job
MMEL 24-30-09A
EXTERNAL POWER PANEL ADIRU/AVNCS VENT CAUTION LIGHT (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 21-26-00-865-100-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAE02
** ON A/C ALL
123VUAVNCS VENT/BLOWER/FAN1HQAD10
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAC04
Subtask 21-26-00-861-086-A
B. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
NOTE: The energization of the aircraft electrical circuits starts a full test of the ventilation system. The test continues for 2 minutes approximately.
Subtask 21-26-00-860-066-A
C. Aircraft Maintenance Configuration
   (1) On the VENTILATION section of the panel 22VU:
  • make sure that the BLOWER and the EXTRACT pushbutton switches are in the AUTO configuration (pushed, with the FAULT and OVRD legends off).
4. Procedure
Subtask 21-26-00-710-069-A
A. Operational Test of the Mechanic Call Horn
ACTION
RESULT
1.On the circuit breaker panels 49VU and 122VU:
  • open the circuit breakers 3HQ, 5HQ and 6HQ.
On the CAPT and F/O glareshield panels 131VU and 130VU:
  • the MASTER CAUT lights come on and you can hear the single chime.
    After 30 seconds approximately:
  • you can hear the mechanic call horn in the nose landing gear well.
NOTE: The mechanic call horn operates only if engine 1 and engine 2 are stopped.
NOTE: On the panel 108VU, push the RESET pushbutton switch to stop the mechanic call horn.
2.On the circuit breaker panels 49VU and 122VU:
  • Close the circuit breakers 3HQ, 5HQ and 6HQ.

5. Close-up
Subtask 21-26-00-942-085-A
A. Safety Precautions
   (1) Put WARNING NOTICE(S) in position in the cockpit to tell the crew that the ADIRU/AVNCS VENT caution light is inoperative.
   (2) Make an entry in the logbook.
Subtask 21-26-00-862-088-A
B. Aircraft Maintenance Configuration
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).