Extract Fault Warning - Check of the Extract Fan and the VENT AVNCS SYS FAULT Warning
TASK 21-26-00-040-011-A
Extract Fault Warning - Check of the Extract Fan and the VENT AVNCS SYS FAULT Warning
MMEL 21-09-02A
VENT EXTRACT FAULT ALERT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-00-861-077-A
Subtask 21-26-00-869-104-A
Subtask 21-26-00-410-074-A
[Rev.10 from 2021]
2026.04.02 06:11:00 UTC
Extract Fault Warning - Check of the Extract Fan and the VENT AVNCS SYS FAULT Warning
Task Summary
1. Reason for the Job| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| YES | YES | NO | 0.5 | 0.5 | 1 |
MMEL 21-09-02A
VENT EXTRACT FAULT ALERT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 21-26-00-861-077-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-00-865-139-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-26-00-010-073-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 21-26-00-869-104-A
A. In the avionics compartment, make sure that extract fan 18HQ operates correctly:
(1) Do the test that follows:
Subtask 21-26-00-710-063-A (1) Do the test that follows:
| ACTION | RESULT |
|---|---|
On circuit breaker panel 122VU:
| On the upper ECAM display unit:
|
|
|
DELETED
5. Close-upSubtask 21-26-00-410-074-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 21-26-00-941-117-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
B. Make an entry in the logbook.
Subtask 21-26-00-941-098-A DELETED
Subtask 21-26-00-862-077-A D. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).