W DOC AIRBUS | AMM A320F

Extract Fault Warning - Check of the Extract Fan and the VENT AVNCS SYS FAULT Warning


TASK 21-26-00-040-011-A
Extract Fault Warning - Check of the Extract Fan and the VENT AVNCS SYS FAULT Warning


Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESYESNO0.50.51
1. Reason for the Job
MMEL 21-09-02A
VENT EXTRACT FAULT ALERT
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 21-26-00-861-077-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-00-865-139-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-00-010-073-A
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824.
   (2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 21-26-00-869-104-A
A. In the avionics compartment, make sure that extract fan 18HQ operates correctly:
   (1) Do the test that follows:
ACTION
RESULT
On circuit breaker panel 122VU:
  • Open circuit breaker 3HQ.
On the upper ECAM display unit:
  • After approximately 15 seconds, the VENT AVNCS SYS FAULT warning comes into view.
  • Close circuit breaker 3HQ.
  • The VENT AVNCS SYS FAULT warning goes out of view.
  • The self-test of the extract fan starts and continues to operate for approximately 60 seconds. You hear the extract fan operate.
Subtask 21-26-00-710-063-A
DELETED
5. Close-up
Subtask 21-26-00-410-074-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
   (3) Remove the access platform(s).
Subtask 21-26-00-941-117-A
B. Make an entry in the logbook.
Subtask 21-26-00-941-098-A
DELETED
Subtask 21-26-00-862-077-A
D. Aircraft Maintenance Configuration
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:11:00 UTC