Skin-Exchanger Isolation Valve Inoperative - Check of the Open Position of the Valve
TASK 21-26-00-040-008-A
Skin-Exchanger Isolation Valve Inoperative - Check of the Open Position of the Valve
MMEL 21-26-06A
AVIONICS SKIN EXCHANGER ISOLATION VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-26-00-861-065-A
Subtask 21-26-00-040-060-A
Subtask 21-26-00-410-070-A
[Rev.10 from 2021]
2026.04.02 06:10:59 UTC
Skin-Exchanger Isolation Valve Inoperative - Check of the Open Position of the Valve
Task Summary
1. Reason for the Job| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| YES | YES | NO | 0.2 | 0.2 | 1 |
MMEL 21-26-06A
AVIONICS SKIN EXCHANGER ISOLATION VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-26-00-710-001-A | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| TASK 21-26-00-710-001-A-01 | Operational Check of the Avionics Equipment Ventilation (without the CFDS) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-26-00-861-065-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-00-010-069-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 822.
(2) Open the access door 822.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 822.
(2) Open the access door 822.
Subtask 21-26-00-040-060-A
A. Check of the Open Position of the Valve
(1) In the avionics compartment:
5. Close-up(1) In the avionics compartment:
- Make sure that the skin-exchanger isolation valve 24HQ is open (the position indicator of the valve is at 0).
CAUTION:
AFTER THE DEACTIVATION OF THE APPLICABLE VALVE, MAKE SURE THAT YOU DO THE OPERATIONAL TEST OF THE AVIONICS-EQUIPMENT VENTILATION-SYSTEM BEFORE EACH FLIGHT.
(2) Do an operational test of the avionics equipment ventilation from the MCDU (Ref. AMM TASK 21-26-00-710-001). NOTE: Make sure that all the fault messages shown are related to the fault of the skin-exchanger isolation valve. If other messages are shown, refer to the related MMEL valve item.
Subtask 21-26-00-410-070-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 822.
(3) Remove the access platform(s).
Subtask 21-26-00-942-075-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 822.
(3) Remove the access platform(s).
B. Safety Precautions
(1) Put a WARNING NOTICE(S) in position in the cockpit to tell the crew that the skin-exchanger isolation valve is deactivated.
(2) Make an entry in the logbook.
Subtask 21-26-00-862-065-A (1) Put a WARNING NOTICE(S) in position in the cockpit to tell the crew that the skin-exchanger isolation valve is deactivated.
(2) Make an entry in the logbook.
C. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Skin Exchanger Isolation Valve