Blower Fan Inoperative - Check that the Air Conditioned Inlet Valve is Open


TASK 21-26-00-040-006-A
Blower Fan Inoperative - Check that the Air Conditioned Inlet Valve is Open


Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESYESNO0.50.51
1. Reason for the Job
MMEL 21-26-01B
AVIONICS BLOWER FAN
MMEL 12-34-56B
AVIONICS BLOWER FAN (FUNC-CODE:21-26-01 ITEM-LIST-NBR:01)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 21-26-00-861-074-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-26-00-010-064-A
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
   (2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 21-26-00-040-055-A
A. Conditioned Air Inlet Valve
   (1) On the VENTILATION part of the overhead control and indicating panel 22VU:
  • release the BLOWER pushbutton switch (the OVRD legend comes on).
   (2) In the avionics compartment:
  • make sure that the conditioned-air inlet valve 21HQ is open (the position indicator of the valve is at 0).
5. Close-up
Subtask 21-26-00-410-065-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
   (3) Remove the access platform(s).
Subtask 21-26-00-941-092-A
B. Aircraft Maintenance Configuration
   (1) Put a WARNING NOTICE(S) in the cockpit to tell the crew that the Blower Fan is deactivated.
   (2) Make an entry in the logbook.
Subtask 21-26-00-862-082-A
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).