Repair of the Individual Air Outlet
TASK 21-24-00-340-001-A
Repair of the Individual Air Outlet
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 21-24-00-861-050-A Subtask 21-24-00-010-050-A 4. Procedure
Subtask 21-24-00-020-051-A
Subtask 21-24-00-410-050-A Subtask 21-24-00-862-050-A
[Rev.10 from 2021]
2026.04.02 06:10:56 UTC
Repair of the Individual Air Outlet
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobNOTE: This procedure is not applicable for the air outlet panel PN Z345H series.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CLOTH-EMERY (GRADE 320) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBD1) | Non Aqueous Cleaner-- Isopropyl Alcohol - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| No specific | HYSOL EPS 462 adhesive |
| No specific | adhesive tape |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-24-19-000-001-A | Removal of the Individual Air Outlet |
| TASK 21-24-19-400-001-A | Installation of the Individual Air Outlet |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-24-00-861-050-A Subtask 21-24-00-010-050-A 4. Procedure
Subtask 21-24-00-020-051-A
A. Turn the nozzle sleeve (3) counterclockwise to retract the poppet valve (1).
Subtask 21-24-00-340-050-A B. Repair of the Individual Air Outlet
(2) Make rough the surfaces to be bonded with CLOTH-EMERY (GRADE 320).
(3) Clean the rough surfaces with a Textile-Lint free Cotton - (Material No.14SBA1) moistened with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) and allow to dry.
(4) Apply a thin coat of HYSOL EPS 462 adhesive onto all the surfaces to be bonded (the nozzle cap (2) and the nozzle sleeve (3)).
(5) Put the nozzle cap (2) in position on the nozzle sleeve (3).
(6) Secure the nozzle cap (2) to the air outlet assembly (4) with the adhesive tape.
(7) Let the adhesive dry for the time recommended by the adhesive manufacturer.
(8) Carefully remove the adhesive tape.
Subtask 21-24-00-710-050-A WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Remove the used adhesive deposits from the surfaces of the nozzle cap (2) and the nozzle sleeve (3) with a Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) . (2) Make rough the surfaces to be bonded with CLOTH-EMERY (GRADE 320).
(3) Clean the rough surfaces with a Textile-Lint free Cotton - (Material No.14SBA1) moistened with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) and allow to dry.
(4) Apply a thin coat of HYSOL EPS 462 adhesive onto all the surfaces to be bonded (the nozzle cap (2) and the nozzle sleeve (3)).
(5) Put the nozzle cap (2) in position on the nozzle sleeve (3).
(6) Secure the nozzle cap (2) to the air outlet assembly (4) with the adhesive tape.
(7) Let the adhesive dry for the time recommended by the adhesive manufacturer.
(8) Carefully remove the adhesive tape.
C. Operational Test of the Individual Air-Outlet mechanism
(1) Turn the nozzle cap (2) in both directions with sufficient torque to move the ball assembly.
(2) Make sure that the nozzle cap (2) is not disengaged from the nozzle sleeve (3), and that the poppet valve (1) operates correctly.
5. Close-up(1) Turn the nozzle cap (2) in both directions with sufficient torque to move the ball assembly.
(2) Make sure that the nozzle cap (2) is not disengaged from the nozzle sleeve (3), and that the poppet valve (1) operates correctly.
Subtask 21-24-00-410-050-A Subtask 21-24-00-862-050-A
Air Outlet Repair