Reactivation of the Lavatory/Galley Extraction Fan
TASK 21-23-00-440-001-A
Reactivation of the Lavatory/Galley Extraction Fan
MMEL 21-23-01A
LAVATORY AND GALLEY EXTRACTION FAN (FAA ONLY)
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 21-23-00-861-054-A 4. Procedure
Subtask 21-23-00-865-053-A
Subtask 21-23-00-862-054-A
[Rev.10 from 2021]
2026.04.02 06:10:56 UTC
Reactivation of the Lavatory/Galley Extraction Fan
FIN: 1HU
1. Reason for the JobMMEL 21-23-01A
LAVATORY AND GALLEY EXTRACTION FAN (FAA ONLY)
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-61-00-710-001-A | Operational Test of the Pack Temperature-Control System |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-23-00-861-054-A 4. Procedure
Subtask 21-23-00-865-053-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-23-00-710-051-A Subtask 21-23-00-440-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL | 5HU | U21 |
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY | 6HU | U19 |
C. Placard
(1) Remove the deactivation placard in the cockpit.
5. Close-up(1) Remove the deactivation placard in the cockpit.
Subtask 21-23-00-862-054-A