Deactivation of the Lavatory/Galley Extraction Fan
TASK 21-23-00-040-001-A
Deactivation of the Lavatory/Galley Extraction Fan
1. Reason for the Job
MMEL 21-23-01A
LAVATORY AND GALLEY EXTRACTION FAN (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 21-23-00-861-053-A 4. Procedure
Subtask 21-23-00-865-052-A
Subtask 21-23-00-862-053-A
[Rev.10 from 2021]
2026.04.02 06:10:56 UTC
Deactivation of the Lavatory/Galley Extraction Fan
1. Reason for the Job
MMEL 21-23-01A
LAVATORY AND GALLEY EXTRACTION FAN (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-23-00-861-053-A 4. Procedure
Subtask 21-23-00-865-052-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 21-23-00-040-050-B | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL | 5HU | U21 |
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY | 6HU | U19 |
B. Deactivation of the Lavatory/Galley Extraction Fan
(1) Make sure that:
Subtask 21-23-00-862-055-A (1) Make sure that:
- on the lower ECAM display unit COND page the cabin duct temperatures are shown.
C. Placard
(1) Put a placard in the cockpit to tell persons that the lavatory/galley extraction fan is deactivated.
(2) Make an entry in the logbook.
Subtask 21-23-00-869-050-A (1) Put a placard in the cockpit to tell persons that the lavatory/galley extraction fan is deactivated.
(2) Make an entry in the logbook.
D. Cockpit Effects
(1) The message LAV DET may be erroneously displayed on the SD INOP SYS status page.
5. Close-up(1) The message LAV DET may be erroneously displayed on the SD INOP SYS status page.
Subtask 21-23-00-862-053-A