W DOC AIRBUS | AMM A320F

Installation of the CAPT (F/O) Individual Air-Outlet


TASK 21-21-44-400-001-A
Installation of the CAPT (F/O) Individual Air-Outlet


ZONE: 211
ZONE: 212
FIN: 4500HM
FIN: 4501HM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 31-53-21-400-001-A
Installation of the Loudspeakers
3. Job Set-up
Subtask 21-21-44-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 21-21-44-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4500HM (AIR OUTLETINDIVIDUAL, COCKPIT)
122VUAIR COND/RECIRC FAN/L/CTL2HGX20
122VUAIR COND/RECIRC FAN/L/SPLY1HGX18
FOR FIN: 4501HM (AIR OUTLETINDIVIDUAL, COCKPIT)
122VUAIR COND/RECIRC FAN/R/CTL11HGW20
122VUAIR COND/RECIRC FAN/R/SPLY3HGW18
4. Procedure
Subtask 21-21-44-420-050-B
A. Installation of the CAPT (F/O) Individual Air-Outlet
   (1) Put the air outlet (5) in position on the duct (6).
   (2) Put the duct (6) with the air outlet (5) in position on the instrument panel (1).
   (3) Install the 4 screws (2) and tighten.
   (4) Put the instrument panel (1) in position.
   (5) Install the 3 washers (3) and the 3 screws (4). Tighten the screws.
   (6) Install the loudspeaker (Ref. AMM TASK 31-53-21-400-001):
     (a) FOR [4500HM] (AIR OUTLET-INDIVIDUAL, COCKPIT)
Install the loudspeaker 7WW.
     (b) FOR [4501HM] (AIR OUTLET-INDIVIDUAL, COCKPIT)
Install the loudspeaker 8WW.
5. Close-up
Subtask 21-21-44-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4500HM (AIR OUTLETINDIVIDUAL, COCKPIT)
122VUAIR COND/RECIRC FAN/L/CTL2HGX20
122VUAIR COND/RECIRC FAN/L/SPLY1HGX18
FOR FIN: 4501HM (AIR OUTLETINDIVIDUAL, COCKPIT)
122VUAIR COND/RECIRC FAN/R/CTL11HGW20
122VUAIR COND/RECIRC FAN/R/SPLY3HGW18
Subtask 21-21-44-862-050-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:10:55 UTC