Removal of the Third (Fourth) Occupant Individual Air-Outlet
TASK 21-21-44-000-002-A
Removal of the Third (Fourth) Occupant Individual Air-Outlet
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-21-44-861-051-A Subtask 21-21-44-865-053-A
Subtask 21-21-44-020-052-B
[Rev.10 from 2021]
2026.04.02 06:10:55 UTC
Removal of the Third (Fourth) Occupant Individual Air-Outlet
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 21-21-44-861-051-A Subtask 21-21-44-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/RECIRC FAN/L/CTL | 2HG | X20 |
| 122VU | AIR COND/RECIRC FAN/L/SPLY | 1HG | X18 |
Subtask 21-21-44-020-052-B
A. Removal of the Third Occupant Individual Air-Outlet
(1) Remove the 4 screws (7) and remove the lining panel (6).
(2) Loosen the 4 quarter-turn fasteners (5) and disengage the plate (4) from the frame (3).
(3) Remove only the 4 applicable screws (8) and remove the plate (4).
(4) Disengage the duct (1) and remove the air-outlet (2).
(1) Remove the 4 screws (7) and remove the lining panel (6).
(2) Loosen the 4 quarter-turn fasteners (5) and disengage the plate (4) from the frame (3).
(3) Remove only the 4 applicable screws (8) and remove the plate (4).
(4) Disengage the duct (1) and remove the air-outlet (2).
Third (Fourth) Occupant Individual Air-Outlet