W DOC AIRBUS | AMM A320F

Removal of the Recirculation Check Valve


TASK 21-21-42-000-001-A
Removal of the Recirculation Check Valve


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the recirculation check valves 4020HM (4021HM).
FIN: 4020HM
FIN: 4021HM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
825
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 25-54-12-000-001-A
Removal of the Forward Cargo-Compartment Partition
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
FOR [4020HM] (RECIRC CHECK VALVE 1)
TASK 06-41-53-00
FUSELAGE-DESCRIPTION AND OPERATION
FOR [4021HM] (RECIRC CHECK VALVE 2)
TASK 06-41-53-00
FUSELAGE-DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 21-21-42-861-050-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-21-42-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4020HM (RECIRC CHECK VALVE 1)
122VUAIR COND/RECIRC FAN/L/CTL2HGX20
122VUAIR COND/RECIRC FAN/L/SPLY1HGX18
FOR FIN: 4021HM (RECIRC CHECK VALVE 2)
122VUAIR COND/RECIRC FAN/R/CTL11HGW20
122VUAIR COND/RECIRC FAN/R/SPLY3HGW18
Subtask 21-21-42-941-050-A
C. Safety Precautions
   (1) On AIR COND panel 30VU:
     (a) Make sure that:
       1 The APU BLEED pushbutton switch is in the off position (the ON legend is off).
       2 The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
     (b) Put a WARNING NOTICE(S) in position to tell the persons not to operate these pushbutton switches.
   (2) On the High Pressure (HP) ground connector put the WARNING NOTICE(S) in position to tell persons not to supply ground air.
Subtask 21-21-42-010-050-A
D. Get Access
   (1) Open FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (2) Put an ACCESS PLATFORM 2M (6 FT) in position at FWD cargo-compartment door 825.
   (3) Remove the access panel(s) from partition FR34 (Ref. AMM TASK 25-54-12-000-001):
     (a) FOR [4020HM] (RECIRC CHECK VALVE 1)
     (b) FOR [4021HM] (RECIRC CHECK VALVE 2)
4. Procedure
Subtask 21-21-42-020-050-A
A. Removal of the Recirculation Check Valve
   (1) Remove the clamp (4) and disconnect the sleeve (5).
   (2) Remove the clamp (1).
   (3) Carefully remove the flange (3) together with the recirculation check valve (2).
   (4) Remove the recirculation check valve (2) from the flange (3).
   (5) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.02 06:10:54 UTC