Flushing of the Blue Hydraulic System of the Slat Power Control-Unit (PCU)
TASK 12-36-29-170-010-A
Flushing of the Blue Hydraulic System of the Slat Power Control-Unit (PCU)
To flush the Blue hydraulic system after a failure in that part of the slat PCU 6001CM.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 12-36-29-860-077-A
Subtask 12-36-29-170-059-A
Subtask 12-36-29-860-079-A
[Rev.10 from 2021]
2026.04.02 06:10:39 UTC
Flushing of the Blue Hydraulic System of the Slat Power Control-Unit (PCU)
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
FIN: 6001CM
1. Reason for the JobTo flush the Blue hydraulic system after a failure in that part of the slat PCU 6001CM.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | 1 | CONTAINER 5 L (1.32 USGAL) |
| No specific | 1 | LOCALLY MANUFACTURED - ADAPTER |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | 1 | WARNING NOTICE(S) |
| ALT29000001 | 1 | HYD GRND PWR UNIT3000 |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 197EB, 197FB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-10-00-863-003-A | Pressurize the Blue Hydraulic System with a Hydraulic Ground Power-Cart |
| TASK 29-10-00-863-003-A-01 | Pressurize the Blue Hydraulic System with the Blue Electric Pump |
| TASK 29-10-00-864-003-A | Depressurize the Blue Hydraulic System |
| TASK 29-12-44-610-001-A | Servicing of the LP-Filter |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
Subtask 12-36-29-860-077-A
A. Aircraft Maintenance Configuration
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(2) Depressurize the Blue hydraulic system (Ref. AMM TASK 29-10-00-864-003).
(3) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 12-36-29-010-093-A (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(2) Depressurize the Blue hydraulic system (Ref. AMM TASK 29-10-00-864-003).
(3) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
B. Get Access
(1) Open the left MLG door (Ref. AMM TASK 32-12-00-010-001).
(2) Open the access doors 197EB 197FB.
Subtask 12-36-29-860-078-A (1) Open the left MLG door (Ref. AMM TASK 32-12-00-010-001).
(2) Open the access doors 197EB 197FB.
C. Preparation for the Flushing Procedure
(1) Put the WARNING NOTICE(S) in position.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the Zone 147.
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE at the Zone 197.
(5) Put a CONTAINER 5 L (1.32 USGAL) to collect the hydraulic fluid leakage below:
(7) Disconnect the pressure line from the valve block 25CV in the Blue hydraulic system of the slat PCU 6001CM.
(8) Disconnect the case drain line from the LP filter 2002GM.
(9) Connect the pressure line to the case drain line at the slat PCU 6001CM with an union.
(11) Connect the pressure hose of the ALT29000001 HYD GRND PWR UNIT3000 to the delivery connector 2008GM with an LOCALLY MANUFACTURED - ADAPTER.
(12) Connect the return hose of the ALT29000001 HYD GRND PWR UNIT3000 to the case drain line with an LOCALLY MANUFACTURED - ADAPTER.
(13) Put the PLUG-BLANKING in each disconnected line end.
4. Procedure(1) Put the WARNING NOTICE(S) in position.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the Zone 147.
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE at the Zone 197.
(5) Put a CONTAINER 5 L (1.32 USGAL) to collect the hydraulic fluid leakage below:
- the slat PCU 6001CM,
- the LP filter 2002GM.
(7) Disconnect the pressure line from the valve block 25CV in the Blue hydraulic system of the slat PCU 6001CM.
(8) Disconnect the case drain line from the LP filter 2002GM.
(9) Connect the pressure line to the case drain line at the slat PCU 6001CM with an union.
CAUTION:
MAKE SURE THAT THE FLOW RATE AND THE SUPPLY PRESSURE ON THE GROUND HYDRAULIC CART ARE SET TO A MINIMUM.
(10) Put the ALT29000001 HYD GRND PWR UNIT3000 in position as necessary. (11) Connect the pressure hose of the ALT29000001 HYD GRND PWR UNIT3000 to the delivery connector 2008GM with an LOCALLY MANUFACTURED - ADAPTER.
(12) Connect the return hose of the ALT29000001 HYD GRND PWR UNIT3000 to the case drain line with an LOCALLY MANUFACTURED - ADAPTER.
(13) Put the PLUG-BLANKING in each disconnected line end.
Subtask 12-36-29-170-059-A
A. Flush the Blue hydraulic system.
(1) Operate the hydraulic power cart for 20 s at 20 bar (290.0754 psi).
(2) Stop the hydraulic power cart.
Subtask 12-36-29-960-059-A 5. Close-up(1) Operate the hydraulic power cart for 20 s at 20 bar (290.0754 psi).
(2) Stop the hydraulic power cart.
Subtask 12-36-29-860-079-A
A. Put the system back to the serviceable condition.
(1) Disconnect the pressure hose and the adaptor from the delivery connector 2008GM.
(2) Disconnect the return hose and the adaptor from the case drain line.
(3) Disconnect and remove the union from the case drain line and the pressure line at the slat PCU 6001CM.
(4) Remove the hydraulic power cart.
(5) Remove the blanking plugs.
(6) Connect the case drain line to the LP filter 2002GM.
(7) Connect the case drain line to the motor in the Blue hydraulic system of the slat PCU 6001CM.
(8) Connect the pressure line to the valve block 25CV in the Blue hydraulic system of the slat PCU 6001CM.
Subtask 12-36-29-790-059-A (1) Disconnect the pressure hose and the adaptor from the delivery connector 2008GM.
(2) Disconnect the return hose and the adaptor from the case drain line.
(3) Disconnect and remove the union from the case drain line and the pressure line at the slat PCU 6001CM.
(4) Remove the hydraulic power cart.
(5) Remove the blanking plugs.
(6) Connect the case drain line to the LP filter 2002GM.
(7) Connect the case drain line to the motor in the Blue hydraulic system of the slat PCU 6001CM.
(8) Connect the pressure line to the valve block 25CV in the Blue hydraulic system of the slat PCU 6001CM.
B. Leak Test of the Components which were Disconnected
(1) Pressurize the Blue hydraulic system of the (Ref. AMM TASK 29-10-00-863-003).
(2) Make sure that there is no hydraulic fluid leakage.
(3) Depressurize the Blue hydraulic system of the (Ref. AMM TASK 29-10-00-864-003).
Subtask 12-36-29-942-098-A (1) Pressurize the Blue hydraulic system of the (Ref. AMM TASK 29-10-00-863-003).
(2) Make sure that there is no hydraulic fluid leakage.
(3) Depressurize the Blue hydraulic system of the (Ref. AMM TASK 29-10-00-864-003).
C. Put the aircraft back to its initial configuration.
(1) Remove the containers.
(2) Remove the safety barriers.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 12-36-29-410-080-A (1) Remove the containers.
(2) Remove the safety barriers.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left MLG door (Ref. AMM TASK 32-12-00-410-001).
(3) Close the access doors 197EB 197FB.
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left MLG door (Ref. AMM TASK 32-12-00-410-001).
(3) Close the access doors 197EB 197FB.
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Blue Hydraulic System of the Slat PCU 6001CM - Flushing Schematic