Clean Grid of Relay Box VU Panels
TASK 12-21-13-100-002-A
Clean Grid of Relay Box VU Panels
Refer to the MPD TASK: 212600-09
CLEAN GRID OF RELAY BOX VU PANELS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 12-21-13-010-051-A
Subtask 12-21-13-140-050-A
Subtask 12-21-13-410-051-A
[Rev.10 from 2021]
2026.04.02 06:10:26 UTC
Clean Grid of Relay Box VU Panels
NOTE: This task can contribute to fuel savings.
1. Reason for the JobRefer to the MPD TASK: 212600-09
CLEAN GRID OF RELAY BOX VU PANELS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | BRUSH - BRISTLED, SOFT |
| No specific | AR | VACUUM CLEANER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 812, 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 12-21-13-010-051-A
A. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access doors 812 and 822.
(2) Open the access doors 812 and 822.
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access doors 812 and 822.
(2) Open the access doors 812 and 822.
Subtask 12-21-13-140-050-A
A. Cleaning of the Grids of the Annunciator-Light Test Unit 70VU
(2) Clean the grid on the right side of the 70VU.
(3) Clean the grid at the bottom of the 70VU.
Subtask 12-21-13-140-051-A NOTE: In the avionics compartment, use a VACUUM CLEANER and a BRUSH - BRISTLED, SOFT to clean the equipments.
Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
(1) Clean the grid on the left side of the 70VU. Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
(2) Clean the grid on the right side of the 70VU.
(3) Clean the grid at the bottom of the 70VU.
B. Cleaning of the Grids of the Relay Box 103VU
(2) Open the door of the relay box 103VU.
(3) Clean the left and right internal grids.
(4) Close the door of the relay box 103VU.
Subtask 12-21-13-140-052-A NOTE: In the avionics compartment, use a vacuum cleaner and a soft brush to clean the equipments.
Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
(1) Clean the left and right external grids of the relay box 103VU. Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
(2) Open the door of the relay box 103VU.
(3) Clean the left and right internal grids.
(4) Close the door of the relay box 103VU.
C. Cleaning of the Grid of the AC/DC Emergency Power-Center 106VU
Subtask 12-21-13-140-053-A NOTE: In the avionics compartment, use a vacuum cleaner and a soft brush to clean the equipments.
Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
(1) Clean the front face of the 106VU. Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
D. Cleaning of the Grid of the Contactor Box 107VU
5. Close-upNOTE: In the avionics compartment, use a vacuum cleaner and a soft brush to clean the equipments.
Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
(1) Clean the front face of the contactor box 107VU. Keep the vacuum cleaner out of the avionics compartment to prevent dust contamination.
Subtask 12-21-13-410-051-A
Location of Units in Avionics Compartment