Inspection/Check of the Level and Pressure of the Rain Repellent Fluid
TASK 12-17-30-200-001-A
Inspection/Check of the Level and Pressure of the Rain Repellent Fluid
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 12-17-30-010-050-A ** ON A/C NOT FOR ALL
Subtask 12-17-30-210-050-C ** ON A/C NOT FOR ALL
Subtask 12-17-30-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:10:23 UTC
Inspection/Check of the Level and Pressure of the Rain Repellent Fluid
NOTE: If there is leakage of FORALKYL 2211, you can smell a pine odor.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 30-45-00-600-001-A | Servicing of the Rain Repellent Fluid Can |
Subtask 12-17-30-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) In the cockpit open the access door to the rain repellent fluid can.
4. Procedure(1) In the cockpit open the access door to the rain repellent fluid can.
Subtask 12-17-30-210-050-C ** ON A/C NOT FOR ALL
A. Inspection/Check of the Level and Pressure of the Rain Repellent Fluid
(1) On the rain repellent fluid gage:
(a) On the pressure indicator, make sure that the pointer points to the green area (if the pointer points to the yellow area, the can should be replaced at next opportunity) (Ref. AMM TASK 30-45-00-600-001).
(b) On the quantity indicator, make sure that there is sufficient rain-repellent fluid (if you see the surface of the fluid, replace the can) (Ref. AMM TASK 30-45-00-600-001).
5. Close-up(1) On the rain repellent fluid gage:
(a) On the pressure indicator, make sure that the pointer points to the green area (if the pointer points to the yellow area, the can should be replaced at next opportunity) (Ref. AMM TASK 30-45-00-600-001).
(b) On the quantity indicator, make sure that there is sufficient rain-repellent fluid (if you see the surface of the fluid, replace the can) (Ref. AMM TASK 30-45-00-600-001).
Subtask 12-17-30-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Close the access door to the rain repellent fluid can.
(1) Close the access door to the rain repellent fluid can.
Rain-Repellent Fluid Gage