W DOC AIRBUS | AMM A320F

Drain and Refill Offset Gearboxes of Rotary Actuators with Semi-fluid


TASK 12-13-27-612-004-A
Drain and Refill Offset Gearboxes of Rotary Actuators with Semi-fluid


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
ZONE: 147
ZONE: 148
ZONE: 573
ZONE: 575
ZONE: 673
ZONE: 675
FIN: 6205CM ** ON A/C NOT FOR ALL
FIN: 6211CM ** ON A/C NOT FOR ALL
FIN: 6221CM ** ON A/C NOT FOR ALL
FIN: 6233CM ** ON A/C NOT FOR ALL
FIN: 6255CM ** ON A/C NOT FOR ALL
FIN: 6261CM ** ON A/C NOT FOR ALL
FIN: 6271CM ** ON A/C NOT FOR ALL
FIN: 6283CM ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 275449-03
DRAIN AND REFILL OFFSET GEARBOXES OF ROTARY ACTUATORS WITH SEMI-FLUID
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 0.44 and 0.36 m.daN (38.94 and 31.86 lbf.in ) T
No specific
Torque wrench: range to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in ) T
460005835
1
SLEEVE - GROUND LOCK
98D27803000000
1
LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION
A663160
1
REPLENISHMENT KIT
FOR [6205CM] (FLAP ACTUATOR 1)
FOR [6255CM] (FLAP ACTUATOR 1)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [6211CM] (FLAP ACTUATOR 2)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [6221CM] (FLAP ACTUATOR 3)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [6233CM] (FLAP ACTUATOR 4)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [6261CM] (FLAP ACTUATOR 2)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [6271CM] (FLAP ACTUATOR 3)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
FOR [6283CM] (FLAP ACTUATOR 4)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03GDB1)
Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid -
(Material No.06LCG9)
Non Hardening Jointing Putty-Medium Temp. Area - -
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
147
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
148
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
573
FIXED STRUCT FROM STA 1800 TO STA 4666
575
AFT OUTBD SE OF WING AND TE FIXED STRUCT
673
FIXED STRUCT FROM STA 1800 TO STA 4666
675
AFT OUTBD SE OF WING AND TE FIXED STRUCT
FOR [6205CM] (FLAP ACTUATOR 1)
FOR [6255CM] (FLAP ACTUATOR 1)
734, 744
FOR [6211CM] (FLAP ACTUATOR 2)
573AB
FOR [6221CM] (FLAP ACTUATOR 3)
575BB
FOR [6233CM] (FLAP ACTUATOR 4)
575FB
FOR [6261CM] (FLAP ACTUATOR 2)
673AB
FOR [6271CM] (FLAP ACTUATOR 3)
675BB
FOR [6283CM] (FLAP ACTUATOR 4)
675FB
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
FOR [6205CM] (FLAP ACTUATOR 1)
FOR [6255CM] (FLAP ACTUATOR 1)
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
FOR [6211CM] (FLAP ACTUATOR 2)
TASK 57-51-37-000-002-A
Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
TASK 57-51-37-400-002-A
Installation of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
FOR [6221CM] (FLAP ACTUATOR 3)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [6233CM] (FLAP ACTUATOR 4)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [6261CM] (FLAP ACTUATOR 2)
TASK 57-51-37-000-002-A
Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
TASK 57-51-37-400-002-A
Installation of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
FOR [6271CM] (FLAP ACTUATOR 3)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
FOR [6283CM] (FLAP ACTUATOR 4)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
TASK 57-51-37-400-004-A
Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
3. Job Set-up
Subtask 12-13-27-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Put a WARNING NOTICE(S) in position in the cockpit to tell persons not to operate the flight controls.
   (2) Put a WARNING NOTICE(S) in position to tell persons not to operate the landing gear doors.
   (3) Put the SAFETY BARRIER(S) in position.
Subtask 12-13-27-860-052-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Extend the flaps fully (Ref. AMM TASK 27-50-00-866-008).
   (2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is in position on the slat/flap control lever.
Subtask 12-13-27-865-057-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 12-13-27-010-056-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) FOR [6205CM] (FLAP ACTUATOR 1), [6255CM] (FLAP ACTUATOR 1)
     (a) Open the applicable Main Landing Gear (MLG) door 734 744 (Ref. AMM TASK 32-12-00-010-001).
     (b) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed.
     (c) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position in the applicable MLG bay.
   (2) FOR [6211CM] (FLAP ACTUATOR 2)
     (a) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below zone 573.
     (b) Remove the access panel 573AB (Ref. AMM TASK 57-51-37-000-002).
   (3) FOR [6261CM] (FLAP ACTUATOR 2)
     (a) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below zone 673.
     (b) Remove the access panel 673AB (Ref. AMM TASK 57-51-37-000-002).
   (4) FOR [6221CM] (FLAP ACTUATOR 3)
     (a) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below zone 575.
     (b) Remove the access panel 575BB (Ref. AMM TASK 57-51-37-000-004).
   (5) FOR [6271CM] (FLAP ACTUATOR 3)
     (a) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below zone 675.
     (b) Remove the access panel 675BB (Ref. AMM TASK 57-51-37-000-004).
   (6) FOR [6233CM] (FLAP ACTUATOR 4)
     (a) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below zone 575.
     (b) Remove the access panel 575FB (Ref. AMM TASK 57-51-37-000-004).
   (7) FOR [6283CM] (FLAP ACTUATOR 4)
     (a) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below zone 675.
     (b) Remove the access panel 675FB (Ref. AMM TASK 57-51-37-000-004).
4. Procedure
CAUTION: DO NOT GET SEMI-FLUID LUBRICANT ON PLASTIC OR RUBBER MATERIALS. SEMI-FLUID LUBRICANT CAN CAUSE DAMAGE TO THE SURFACE. REMOVE UNWANTED SEMI-FLUID LUBRICANT WITH A LINT FREE CLOTH.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Subtask 12-13-27-612-053-A ** ON A/C NOT FOR ALL
A. Replenishment of the Offset Gearboxes of the No.1 Flap Actuators (6205CM,6255CM)
   (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the area around the vent plug (1), and the drain plug (2).
   (2) Remove the vent plug (1), and the drain plug (2).
   (3) Use the A663160 REPLENISHMENT KIT to fill the applicable flap actuator, as follows:
     (a) Install the vent plug adaptor 3/8 UNF (A663159/1) to the vent plug hole of the applicable flap actuator.
     (b) Install the drain plug adaptor 3/8 UNF (A663159/1) to the drain plug hole of the applicable flap actuator.
     (c) Assemble the semi-fluid pump (A663130/3) to the semi-fluid container (A663130/7).
     (d) Connect the supply hose from the semi-fluid pump to the drain plug adaptor.
     (e) Assemble the waste lid (A663130/5) to the used fluid container (A663130/6).
     (f) Connect the waste hose from the waste lid to the vent plug adaptor.
     (g) Use the semi-fluid pump to slowly fill the applicable flap actuator.
     (h) Continue to fill the applicable flap actuator until clean Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) flows from the waste hose.
     (i) Disconnect the supply hose from the drain plug adaptor.
     (j) Disconnect the waste hose from the vent plug adaptor.
     (k) Connect the waste hose to the drain plug adaptor.
     (l) Use the empty oil gun (A663130/4) to pressurize the applicable flap actuator with air, as follows:
       1 Connect the oil gun hose to the vent plug adaptor, slowly pressurize the applicable flap actuator.
       2 Continue to supply air, until air only is released from the waste hose. Stop the air supply.
       3 Remove the oil gun hose and the vent plug adaptor.
       4 Remove the waste hose and the drain plug adaptor.
       5 Clean the applicable component interfaces and the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
       6 Make sure that the parts retained from the removed component are clean and in the correct condition.
       7 Do an inspection of the component interfaces and the adjacent area.
       8 Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the vent plug (1), and the drain plug (2).
       9 Install the vent plug (1), and the drain plug (2).
       10 Torque the vent plug (1) to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in ) T.
       11 Torque the drain plug (2) to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in )
T.
Subtask 12-13-27-612-057-A ** ON A/C NOT FOR ALL
B. Replenishment of the Offset Gearboxes of the No.2 Flap Actuators (6211CM,6261CM)
   (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the area around the vent plug (3), and the drain plug (4).
   (2) Remove the vent plug (3), and the drain plug (4).
   (3) Use the A663160 REPLENISHMENT KIT to fill the applicable flap actuator, as follows:
     (a) Install the vent plug adaptor 3/8 UNF (A663159/1) to the vent plug hole of the applicable flap actuator.
     (b) Install the drain plug adaptor 3/8 UNF (A663159/1) to the drain plug hole of the applicable flap actuator.
     (c) Assemble the semi-fluid pump (A663130/3) to the semi-fluid container (A663130/7).
     (d) Connect the supply hose from the semi-fluid pump to the drain plug adaptor.
     (e) Assemble the waste lid (A663130/5) to the used fluid container (A663130/6).
     (f) Connect the waste hose from the waste lid to the vent plug adaptor.
     (g) Use the semi-fluid pump to slowly fill the applicable flap actuator.
     (h) Continue to fill the applicable flap actuator until clean Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) flows from the waste hose.
     (i) Disconnect the supply hose from the drain plug adaptor.
     (j) Disconnect the waste hose from the vent plug adaptor.
     (k) Connect the waste hose to the drain plug adaptor.
     (l) Use the empty oil gun (A663130/4) to pressurize the applicable flap actuator with air, as follows:
       1 Connect the oil gun hose to the vent plug adaptor, slowly pressurize the applicable flap actuator.
       2 Continue to supply air, until air only is released from the waste hose. Stop the air supply.
       3 Remove the oil gun hose and the vent plug adaptor.
       4 Remove the waste hose and the drain plug adaptor.
       5 Clean the applicable component interfaces and the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
       6 Make sure that the parts retained from the removed component are clean and in the correct condition.
       7 Do an inspection of the component interfaces and the adjacent area.
       8 Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the vent plug (3), and the drain plug (4).
       9 Install the vent plug (3), and the drain plug (4).
       10 Torque the vent plug (3) to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in ) T.
       11 Torque the drain plug (4) to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in )
T.
Subtask 12-13-27-612-058-A ** ON A/C NOT FOR ALL
C. Replenishment of the Offset Gearboxes of the No.3 Flap Actuators (6221CM,6271CM)
   (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the area around the vent plug (5), and the drain plug (6).
   (2) Remove the vent plug (5), and the drain plug (6).
   (3) Use the A663160 REPLENISHMENT KIT to fill the applicable flap actuator, as follows:
     (a) Install the vent plug adaptor 3/8 UNF (A663159/1) to the vent plug hole of the applicable flap actuator.
     (b) Install the drain plug adaptor 5/16 UNF (A663159/2) to the drain plug hole of the applicable flap actuator.
     (c) Assemble the semi-fluid pump (A663130/3) to the semi-fluid container (A663130/7).
     (d) Connect the supply hose from the semi-fluid pump to the drain plug adaptor.
     (e) Assemble the waste lid (A663130/5) to the used fluid container (A663130/6).
     (f) Connect the waste hose from the waste lid to the vent plug adaptor.
     (g) Use the semi-fluid pump to slowly fill the applicable flap actuator.
     (h) Continue to fill the applicable flap actuator until clean Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) flows from the waste hose.
     (i) Disconnect the supply hose from the drain plug adaptor.
     (j) Disconnect the waste hose from the vent plug adaptor.
     (k) Connect the waste hose to the drain plug adaptor.
     (l) Use the empty oil gun (A663130/4) to pressurize the applicable flap actuator with air, as follows:
       1 Connect the oil gun hose to the vent plug adaptor, slowly pressurize the applicable flap actuator.
       2 Continue to supply air, until air only is released from the waste hose. Stop the air supply.
       3 Remove the oil gun hose and the vent plug adaptor.
       4 Remove the waste hose and the drain plug adaptor.
       5 Clean the applicable component interfaces and the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
       6 Make sure that the parts retained from the removed component are clean and in the correct condition.
       7 Do an inspection of the component interfaces and the adjacent area.
       8 Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the vent plug (5), and the drain plug (6).
       9 Install the vent plug (5), and the drain plug (6).
       10 Torque the vent plug (5) to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in ) T.
       11 Torque the drain plug (6) to between 0.44 and 0.36 m.daN (38.94 and 31.86 lbf.in )
T.
Subtask 12-13-27-612-059-A ** ON A/C NOT FOR ALL
D. Replenishment of the Offset Gearboxes of the No.4 Flap Actuators (6233CM,6283CM)
   (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the area around the vent plug (7), and the drain plug (8).
   (2) Remove the vent plug (7), and the drain plug (8).
   (3) Use the A663160 REPLENISHMENT KIT to fill the applicable flap actuator, as follows:
     (a) Install the vent plug adaptor 3/8 UNF (A663159/1) to the vent plug hole of the applicable flap actuator.
     (b) Install the drain plug adaptor 5/16 UNF (A663159/2) to the drain plug hole of the applicable flap actuator.
     (c) Assemble the semi-fluid pump (A663130/3) to the semi-fluid container (A663130/7).
     (d) Connect the supply hose from the semi-fluid pump to the drain plug adaptor.
     (e) Assemble the waste lid (A663130/5) to the used fluid container (A663130/6).
     (f) Connect the waste hose from the waste lid to the vent plug adaptor.
     (g) Use the semi-fluid pump to slowly fill the applicable flap actuator.
     (h) Continue to fill the applicable flap actuator until clean Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) flows from the waste hose.
     (i) Disconnect the supply hose from the drain plug adaptor.
     (j) Disconnect the waste hose from the vent plug adaptor.
     (k) Connect the waste hose to the drain plug adaptor.
     (l) Use the empty oil gun (A663130/4) to pressurize the applicable flap actuator with air, as follows:
       1 Connect the oil gun hose to the vent plug adaptor, slowly pressurize the applicable flap actuator.
       2 Continue to supply air, until air only is released from the waste hose. Stop the air supply.
       3 Remove the oil gun hose and the vent plug adaptor.
       4 Remove the waste hose and the drain plug adaptor.
       5 Clean the applicable component interfaces and the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
       6 Make sure that the parts retained from the removed component are clean and in the correct condition.
       7 Do an inspection of the component interfaces and the adjacent area.
       8 Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the vent plug (7), and the drain plug (8).
       9 Install the vent plug (7), and the drain plug (8).
       10 Torque the vent plug (7) to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in ) T.
       11 Torque the drain plug (8) to between 0.44 and 0.36 m.daN (38.94 and 31.86 lbf.in )
T.
5. Close-up
Subtask 12-13-27-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) FOR [
6205CM] (FLAP ACTUATOR 1), [6255CM] (FLAP ACTUATOR 1)
     (a) Close the applicable MLG door 734 744 (Ref. AMM TASK 32-12-00-410-001).
   (3) FOR [6211CM] (FLAP ACTUATOR 2)
     (a) Install the access panel 573AB (Ref. AMM TASK 57-51-37-400-002).
   (4) FOR [6261CM] (FLAP ACTUATOR 2)
     (a) Install the access panel 673AB (Ref. AMM TASK 57-51-37-400-002).
   (5) FOR [6221CM] (FLAP ACTUATOR 3)
     (a) Install the access panel 575BB (Ref. AMM TASK 57-51-37-400-004).
   (6) FOR [6271CM] (FLAP ACTUATOR 3)
     (a) Install the access panel 675BB (Ref. AMM TASK 57-51-37-400-004).
   (7) FOR [6233CM] (FLAP ACTUATOR 4)
     (a) Install the access panel 575FB (Ref. AMM TASK 57-51-37-400-004).
   (8) FOR [6283CM] (FLAP ACTUATOR 4)
     (a) Install the access panel 675FB (Ref. AMM TASK 57-51-37-400-004).
   (9) Remove the 460005835 SLEEVE - GROUND LOCK from the MLG.
   (10) Remove the access platform(s).
Subtask 12-13-27-865-058-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 12-13-27-860-053-A ** ON A/C NOT FOR ALL
C. Put the Aircraft Back to its Original Configuration
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the slat/flap control lever.
   (2) Retract the flaps fully (Ref. AMM TASK 27-50-00-866-009).
Subtask 12-13-27-942-057-A ** ON A/C NOT FOR ALL
D. Removal of Equipment
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the safety barriers.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.02 06:10:18 UTC