W DOC AIRBUS | AMM A320F

General Visual Inspection of Overwing Emergency Exits including Door Surround on Fuselage and Door Seals, External Surface (EWIS)


TASK 05-28-30-200-014-A
General Visual Inspection of Overwing Emergency Exits including Door Surround on Fuselage and Door Seals, External Surface (EWIS)


ZONE: 834
ZONE: 844
1. Reason for the Job
Refer to the MPD TASK: ZL-834-06
GENERAL VISUAL INSPECTION OF OVERWING EMERGENCY EXITS INCLUDING DOOR SURROUND ON FUSELAGE AND DOOR SEALS, EXTERNAL SURFACE (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
834
EMERGENCY EXITS
844
EMERGENCY EXITS
831, 832, 834, 834AZ, 834BZ, 841, 842, 844, 844AZ, 844BZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-47-000-001-A
Removal of the Lining from the Emergency Exit Hatches
TASK 25-23-47-400-001-A
Installation of the Lining on the Emergency Exit Hatches
TASK 52-10-00-010-001-A
Opening of the Passenger/Crew Door
TASK 52-10-00-410-001-A
Closing of the Passenger/Crew Door
TASK 52-21-11-000-001-A
Removal of the Emergency Exit Hatch
TASK 52-21-11-400-001-A
Installation of the Emergency Exit Hatch
3. Job Set-up
Subtask 05-28-30-010-059-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 831 ( 841) or 832 ( 842).
   (2) Open passenger/crew door 831 ( 841) or 832 ( 842) (Ref. AMM TASK 52-10-00-010-001).
   (3) Open emergency exit door 834 ( 844) (Ref. AMM TASK 52-21-11-000-001).
   (4) Remove emergency-exit door panels 834AZ ( 844AZ) and 834BZ ( 844BZ) (Ref. AMM TASK 25-23-47-000-001).
4. Procedure
Subtask 05-28-30-210-063-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a general visual inspection of the overwing emergency exits. This inspection includes the door surround on the fuselage, the door seals and the external surface of the doors.
   (2) Make sure that there are no signs of corrosion, cracks or damage.
   (3) Make sure that all the installations are attached correctly.
5. Close-up
Subtask 05-28-30-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install emergency-exit door panels 834AZ ( 844AZ) and 834BZ ( 844BZ) (Ref. AMM TASK 25-23-47-400-001).
   (2) Close emergency exit door 834 ( 844) (Ref. AMM TASK 52-21-11-400-001).
   (3) Close passenger/crew door 831 ( 841) or 832 ( 842) (Ref. AMM TASK 52-10-00-410-001).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:09:50 UTC