28-11 TANKS
- PB.001 TANKS - DESCRIPTION AND OPERATION
- PB.301 TANKS - SERVICING
-
28-11-00-600-020-A
[10]
Preventative Treatment Procedure for Microbiological Contamination - Biobor Method -
28-11-00-600-021-A
[10]
Curative Treatment Procedure for Microbiological Contamination - Biobor Method -
28-11-00-600-022-A
[10]
Curative Treatment Procedure for Microbiological Contamination - Kathon Method -
28-11-00-600-023-A
[10]
Preventative Treatment Procedure for Microbiological Contamination - Kathon Method -
28-11-00-600-024-A
[10]
Quantification and Treatment of Microbiological Contamination -
28-11-00-600-003-A
[10]
Removal of the Microbiological Particles -
28-11-00-600-011-A
[10]
Preservation of a Center Tank (Not in Use) -
28-11-00-600-008-A
[9]
Biocidal Shock Treatment for Moderate Contamination - With Fuel Mixed with Biobor Biocide -
28-11-00-600-008-A-01
[9]
Biocidal Shock Treatment for Moderate Contamination - With Fuel Mixed with Kathon Biocide -
28-11-00-600-008-A-02
[9]
Biocidal Shock Treatment for Moderate Contamination - Using Biobor Biocide With a Metered Injection Rig -
28-11-00-600-008-A-03
[9]
Biocidal Shock Treatment for Moderate Contamination - Using Kathon Biocide With a Metered Injection Rig -
28-11-00-600-009-A
[9]
Biocidal Shock Treatment for Heavy Contamination - With Fuel Mixed with Biobor Biocide -
28-11-00-600-009-A-01
[9]
Biocidal Shock Treatment for Heavy Contamination - With Fuel Mixed with Kathon Biocide -
28-11-00-600-009-A-02
[9]
Biocidal Shock Treatment for Heavy Contamination - Using Biobor Biocide With a Metered Injection Rig -
28-11-00-600-009-A-03
[9]
Biocidal Shock Treatment for Heavy Contamination - Using Kathon Biocide With a Metered Injection Rig -
28-11-00-600-010-A
[9]
Biocidal Preventative Treatment for Aircraft in Long-Term Storage - With Fuel Mixed with Biobor Biocide -
28-11-00-600-010-A-01
[9]
Biocidal Preventative Treatment for Aircraft in Long-Term Storage - With Fuel Mixed with Kathon Biocide -
28-11-00-600-010-A-02
[9]
Biocidal Preventative Treatment for Aircraft in Long-Term Storage - Using Biobor Biocide With a Metered Injection Rig -
28-11-00-600-010-A-03
[9]
Biocidal Preventative Treatment for Aircraft in Long-Term Storage - Using Kathon Biocide With a Metered Injection Rig
-
28-11-00-600-020-A
[10]
- PB.501 TANKS - ADJUSTMENT/TEST
-
28-11-00-790-001-A
[10]
Leak Test with Fuel of the Wing-Tank Outer-Cell -
28-11-00-790-002-A
[10]
Leak Test with Fuel of the Wing-Tank Outer and Inner Cells -
28-11-00-790-008-A
[10]
Leak Test with Fuel of the Wing Tank -
28-11-00-790-003-A
[10]
Leak Test of the Center Tank -
28-11-00-790-004-A
[10]
Leak Test with Fuel of the Vent Surge Tank -
28-11-00-790-005-A
[10]
Leak Test of the Wing Tanks and Vent Surge Tank (without Fuel) by the Local Blowing Procedure -
28-11-00-790-006-A
[10]
Leak Test of the Wing Tanks and Vent Surge Tank (without Fuel) by the Vacuum and Dye Procedure -
28-11-00-790-007-A
[10]
Leak Test of the Left Wing and Vent Surge Tanks and the Center Tank (without Fuel) by the Vacuum and Dye Procedure -
28-11-00-790-009-A
[10]
Leak Test of the Fuel Tanks - Without Fuel - Helium Procedure -
28-11-00-790-010-A
[10]
Operational Test of the Interspace Overboard Drain System -
28-11-00-790-013-A
[10]
Leak Check of the Additional Center Tank (ACT)-Vent/Transfer Pipe-Shrouds and the ACT Drain-Pipe Connectors -
28-11-00-790-802-A
[10]
Leak Test of the Wing Tanks and the Center Tank - Without Fuel - Pressurized Air and Helium/Air Procedure -
28-11-00-790-803-A
[10]
Definitive Leak Test of the Dry Bay - Without Fuel - Helium Procedure -
28-11-00-790-804-A
[10]
External Temporary Leak Test of the Dry Bay -
28-11-00-790-805-A
[10]
Leak Test of the Wing Tanks - Without Fuel - Pressurized Air and Helium/Air Procedure (Surge Tank is not Included)
-
28-11-00-790-001-A
[10]
- PB.601 TANKS - INSPECTION/CHECK
-
28-11-00-200-002-A
[10]
Operational Check of Leak Monitor for Evidence of Fuel Leakage and Correct Closure of the Valve -
28-11-00-200-003-A
[10]
Check ACT Fuel Leak Monitor for Evidence of Fuel Leakage and Correct Closure of the Valve -
28-11-00-280-002-A
[10]
Structural Fuel Tank Leaks - General Information -
28-11-00-280-003-A
[10]
Structural Fuel Leaks - Analysis of the Route, Location of the Source and the Identification of Applicable Leak Tests -
28-11-00-210-801-A
[10]
General Visual Inspection of Fuel Tanks for Minor External Leaks -
28-11-00-200-001-A
[8]
Check for Full and Free Movement of Clack Valves
-
28-11-00-200-002-A
[10]
- PB.701 TANKS - CLEANING/PAINTING
-
28-11-00-100-001-A
[10]
Cleaning of the Fuel Tanks
-
28-11-00-100-001-A
[10]
- PB.401 TANK - CENTER, ADDITIONAL (ACT) - REMOVAL/INSTALLATION
-
28-11-27-000-001-A
[10]
Removal of the Additional Center Tank (ACT) -
28-11-27-400-001-A
[10]
Installation of the Additional Center Tank (ACT) -
28-11-27-000-002-A
[10]
Removal of Additional Center Tank No.1 (ACT AFT1) -
28-11-27-400-002-A
[10]
Installation of Additional Center Tank No.1 (ACT AFT1) -
28-11-27-000-003-A
[10]
Removal of the Additional Center Tank No.2 (ACT AFT2) -
28-11-27-400-003-A
[10]
Installation of the Additional Center Tank No.2 (ACT AFT2)
-
28-11-27-000-001-A
[10]
- PB.401 COVER - MANHOLE, ACT - REMOVAL/INSTALLATION
-
28-11-37-000-001-A
[10]
Removal of the Inner Manhole-Cover ACT -
28-11-37-400-001-A
[10]
Installation of the Inner Manhole-Cover ACT -
28-11-37-000-004-A
[10]
Removal of the Outer Manhole-Cover ACT -
28-11-37-400-004-A
[10]
Installation of the Outer Manhole Cover ACT
-
28-11-37-000-001-A
[10]
- PB.401 VALVE - WATER DRAIN - REMOVAL/INSTALLATION
-
28-11-41-000-001-A
[10]
Removal of the Water Drain Valve -
28-11-41-400-002-A
[10]
Installation of the Water Drain Valve -
28-11-41-000-002-A
[10]
Removal of the Water Drain Valve -
28-11-41-400-003-A
[10]
Installation of the Water Drain Valve -
28-11-41-000-003-A
[10]
Removal of the Water Drain Valve -
28-11-41-400-004-A
[10]
Installation of the Water Drain Valve -
28-11-41-000-006-A
[10]
Removal of the Outer Valve -
28-11-41-400-005-A
[10]
Installation of the Outer Valve -
28-11-41-000-004-A
[10]
Removal of the Water Drain Valve -
28-11-41-400-006-A
[10]
Installation of the Water Drain Valve -
28-11-41-000-005-A
[10]
Removal of the Outer Valve -
28-11-41-400-007-A
[10]
Installation of the Outer Valve
-
28-11-41-000-001-A
[10]
- PB.401 CLACK VALVE - REMOVAL/INSTALLATION
-
28-11-42-000-001-A
[10]
Removal of the Clack Valve (RIB2) -
28-11-42-400-001-A
[10]
Installation of the Clack Valve (RIB2) -
28-11-42-000-002-A
[10]
Removal of the Clack Valve -
28-11-42-400-002-A
[10]
Installation of the Clack Valve
-
28-11-42-000-001-A
[10]
- PB.401 CAP/ADAPTOR - GRAVITY FILL - REMOVAL/INSTALLATION
-
28-11-43-000-001-A
[10]
Removal of the Gravity Fill Cap/Adaptor -
28-11-43-400-001-A
[10]
Installation of the Gravity Fill Cap/Adaptor
-
28-11-43-000-001-A
[10]
- PB.401 VALVE - WATER DRAIN, ACT - REMOVAL/INSTALLATION
-
28-11-47-000-001-A
[10]
Removal of the ACT Water Drain Valve -
28-11-47-400-001-A
[10]
Installation of the ACT Water Drain Valve -
28-11-47-000-003-A
[10]
Removal of the Additional Center Tank (ACT) Water Drain-Valve -
28-11-47-400-003-A
[10]
Installation of the Additional Center Tank (ACT) Water Drain-Valve -
28-11-47-920-001-A
[10]
Replacement of the Outer Water Drain-Valve of the ACT -
28-11-47-000-802-A
[10]
Removal of the Additional Center Tank (ACT) Outer Drain-Valve -
28-11-47-400-802-A
[10]
Installation of the Additional Center Tank (ACT) Outer Drain-Valve
-
28-11-47-000-001-A
[10]
- PB.401 INTEGRATED IMPACT WALL - ACT - REMOVAL/INSTALLATION
-
28-11-49-000-001-A
[10]
Removal of the ACT Integrated Impact Wall -
28-11-49-400-001-A
[10]
Installation of the ACT Integrated Impact Wall -
28-11-49-000-002-A
[10]
Removal of the Additional Center Tank (ACT) Integrated Impact Wall -
28-11-49-400-002-A
[10]
Installation of the Additional Center Tank (ACT) Integrated Impact Wall
-
28-11-49-000-001-A
[10]