W DOC AIRBUS | AMM A320F

AIDS - WEFA REPORTS - DESCRIPTION AND OPERATION


** ON A/C NOT FOR ALL
1. General
The AIDS Reports are results of the related AIDS monitored aircraft systems (refer to the list below for the list of reports which are available). The reports can be requested manually or are started automatically. The monitor functions have fixed trigger mechanisms, fixed data collection and output formatting. Collected monitored-aircraft-data is automatically supplied to the related systems during unusual aircraft operation. If a report is requested manually with the remote print button, it is generated immediately (independently of any other start logic). The manually or automatically generated reports (stored in the SSMM) can be transferred to the printer and/or the MDDU, and/or the ACARS and/or the DAR/SAR. Some parameters for customer requirements are re-programmable through the MCDU or by GSE (For more information refer to (Ref. AMM D/O 31-36-00-00).
The following AIDS Report is available:
  • <90> WEFA Report.
** ON A/C NOT FOR ALL
2. Reports
A. WEFA Report <90>
The Wireless Extension for AIDS Report contains a mandatory part at the beginning which is related to the WEFA function and must not be changed.
By the use of the GSE you can add optional/additional data to the report.
The WEFA report, described below, is generated when one of the logic conditions (1000 or 4001) is present.
(1) WEFA Report Data Lines Description
The length of the WEFA Report can be different, because there could be an optional part added by the GSE starting at line 21.
The lines up to line ID C4 are mandatory.
(2) WEFA Report Data Field Description
+---------------------------------------------------------------------+
! Value ! Content Description !
!--------------!------------------------------------------------------!
! AIRPORT ! Identification of destionation airport !
! AAAA ! Format: 4 characters, the first are left aligned. !
! ! Source: FMGC !
! ! 01.1.041.XX first digit of AIRPORT !
! ! 01.2.041.XX !
! ! 01.1.042.XX digit 2, 3, 4 of AIRPORT !
! ! 01.2.042.XX !
!--------------!------------------------------------------------------!
! DATE ! Date (Day/Month/Year) !
! 999999 ! Format: DDMMYY !
! ! !
! ! DD: number of the day is numeric value on 2 digits !
! ! MM: number of the month is numeric value on 2 digits!
! ! YY: number of the year is numeric value on 2 digits !
! ! !
! ! Source: FDIU 17.1.260.00 !
! ! Remark: The definition of the parameter "DATE" for !
! ! WEFA report <90> is different from the standard !
! ! definition of "DATE" in all other reports. !
!--------------!------------------------------------------------------!
! FROM ! Identification of origin airport !
! AAAA ! Format: 4 characters, the first are left aligned. !
! ! Source: FMGC !
! ! 01.1.040.XX digits 1, 2, 3 of FROM !
! ! 01.2.040.XX !
! ! 01.1.041.XX digit 4 of FROM !
! ! 01.2.041.XX !
!--------------!------------------------------------------------------!
! FMF ! FWC Flight Phase !
! 99 ! !
! ! Format Binary (bit 11(LSB to 14(MSB)) !
! ! Source FWC 26.1.126.01 !
! ! 26.2.126.01 !
!--------------!------------------------------------------------------!
! EXSWPN(ESWPN)! Extended Software Part Number !
!AAX99XXXXX9999! (Extende Software Identification) !
! ! DMU !
! ! !
! ! A A X99 XXXXX 9999 !
! ! - - --- ----- ---- !
! ! ! ! ! ! ! !
! ! ! ! ! ! ! !
! ! ! ! ! ! !____4 digits of the version of the !
! ! ! ! ! ! database !
! ! ! ! ! !__________4 digits of the Database Number!
! ! ! ! ! with a leading '0" !
! ! ! ! !________________Last 3 digits of the system !
! ! ! ! software PN !
! ! ! !___________________Engine Type 'C'= CFMI; 'I'= IAE!
! ! ! 'P' = PW. !
! ! !_____________________Vendor 'S' = SAGEM !
! ! !
+---------------------------------------------------------------------+

(3) Parameter Logic
+---------------------------------------------------------------------+
! Param ! Print Value (Standard Progr.) !
!--------------!------------------------------------------------------!
! AIRPORT ! Value at moment of trigger !
!--------------!------------------------------------------------------!
! CODE ! Actual trigger code !
!--------------!------------------------------------------------------!
! DATE ! Value at moment of trigger !
!--------------!------------------------------------------------------!
! UTC ! Value at moment of trigger !
!--------------!------------------------------------------------------!
! A/C ID ! Value at moment of trigger !
!--------------!------------------------------------------------------!
! FROM ! Value at moment of trigger !
!--------------!------------------------------------------------------!
! FLT ! Value at moment of trigger !
!--------------!------------------------------------------------------!
! FMF ! Value at moment of trigger !
!--------------!------------------------------------------------------!
! EXSWPN ! Value at moment of trigger !
+---------------------------------------------------------------------+

(4) WEFA Report Logic
+-------------------------------------------------------------------------+
!Code!Item ! !Progr !Standard !
! No.!No. ! Description of Function Item !GSE/MCDU ! Value !
!----!------!-----------------------------------------!---------!---------!
! !A ! Report Format ! ! !
! ! ! ! ! !
! !A.1 ! Not applicable ! ! N/A !
! ! ! ! ! !
! !A.2 ! Not applicable ! ! N/A !
! ! ! ! ! !
! !B ! Parameter Table ! ! !
! ! ! ! ! !
! !C ! First three lines of Report ! N/A ! N/A !
! ! ! ! ! !
! !D ! Print Out Rules ! C ! see !
! ! ! ! ! separate!
! ! ! ! ! list !
! !E ! Not applicable ! ! !
! ! ! ! ! !
! ! ! ! ! !
! !F ! Not applicable ! ! !
! ! ! ! ! !
! !G ! Time counter 'Y90.1' (range of to 20 ! C ! 0 !
! ! ! seconds) ! ! !
!----!------!-----------------------------------------!---------!---------!
!1000!1 ! Manual selection through MCDU ! ! !
!----!------!-----------------------------------------!---------!---------!
!2000!2 ! Not applicable ! ! !
!----!------!-----------------------------------------!---------!---------!
!3000!3 ! Not applicable ! ! !
!----!------!-----------------------------------------!---------!---------!
!4001!4 ! Report is generated if the following ! ! !
! ! ! logic item is present: ! ! !
! ! ! SPC installed in FDIMU ! ! !
! ! ! AND ! ! !
! ! ! Transition of FWC-Flight Phase from 9 to! ! !
! ! ! 10 AND then ! ! !
! ! ! Wait for 'Y90.1' seconds ! ! !
!----!------!-----------------------------------------!---------!---------!
!8100!8.1 ! Not applicable ! ! !
+-------------------------------------------------------------------------+
! A = Programmable by Airbus !
! C = Programmable by Customer !
+-------------------------------------------------------------------------+

B. AIDS Reports Print Rules - Default Values for Report <90>
+-------------------------------------------------------------------------+
!Trigger! to ACARS ! to printer ! store !
! Code !--------------------------------!-----------------!--------------!
! No !Ground ! VHF !SATCOM ! HF ! at ! imme- ! internal& !
! ! ! ! ! !landing ! diate ! external !
! ! ! ! ! ! ! !(build in RAM&!
! ! ! ! ! ! ! ! PCMCIA) !
!-------!-------!--------!-------!-------!--------!--------!--------------!
! 1000 ! NO ! NO ! NO ! NO ! NO ! YES ! YES !
!-------!-------!--------!-------!-------!--------!--------!--------------!
! 4001 ! NO ! NO ! NO ! NO ! NO ! NO ! YES !
+-------------------------------------------------------------------------+

[Rev.10 from 2021] 2026.04.01 08:33:37 UTC