1. General
An electrical razor socket is installed in each lavatory.
** ON A/C NOT FOR ALL
2. Component Location
F Razor Supply - Component Location ** ON A/C NOT FOR ALL
FIN FUNCTIONAL
DESIGNATION
PANEL ZONE ACCESS
DOOR
ATA REF
** ON A/C NOT FOR ALL
2MT INVERTER-STATIC 260 25-44-00
** ON A/C NOT FOR ALL
10MT MINI INVERTER 200 25-44-00
** ON A/C NOT FOR ALL
3. System Description
The razor supply system has:
  • a circuit breaker
  • a static inverter
  • a razor socket in each lavatory (US/European type).
The circuit breaker (1MT) is installed on the panel 2001 VU and protects the system.
The static inverter (2MT) is installed near the panel 2001 VU in the aft cabin overhead-compartment in Zone 263.
The razor sockets (3MT) are installed in the service cabinets of each lavatory.
F Razor Supply - Component Location ** ON A/C NOT FOR ALL
The mini inverter 10MT and a razor power outlet-socket (115V/60HZ) are installed in the service cabinet of each lavatory.
** ON A/C NOT FOR ALL
4. Power Supply
F Electrical - Schematic ** ON A/C NOT FOR ALL
F Power Supply - Schematic ** ON A/C NOT FOR ALL
The service bus 212XP supplies 115V AC/400Hz through the circuit breakers (1MT) to a contact in the razor outlet sockets. When a plug is put into a socket, the contact closes and the power is supplied to the static inverter (2MT). The static inverter (2MT) supplies 110V/60Hz to the razor power-outlet socket.
** ON A/C NOT FOR ALL
5. Component Description
A. Static Inverter
F Static Inverter ** ON A/C NOT FOR ALL