W DOC AIRBUS | AMM A320F

DC GROUND SERVICE BUS CONTROL - DESCRIPTION AND OPERATION


** ON A/C NOT FOR ALL
1. General
F Ground Service Network-General ** ON A/C NOT FOR ALL
F Ground Service Network-General ** ON A/C NOT FOR ALL
DC ground flight distribution network can be supplied:
  • either normally from the aircraft network,
  • or directly by the ground power unit upstream of the external power contactor. This is via the TR2 in ground service configuration, without energizing the whole aircraft network.
** ON A/C NOT FOR ALL
2. Component Location
FIN FUNCTIONAL
DESIGNATION
PANEL ZONE ACCESS
DOOR
ATA REF
** ON A/C ALL
3PX CNTOR-DC SVCE BUS GND SPLY 120VU 212 24-43-55
** ON A/C NOT FOR ALL
3. System Description
F Ground Service Network-General ** ON A/C NOT FOR ALL
F Ground Service Network-General ** ON A/C NOT FOR ALL
The DC ground/flight network comprises the following 28 VDC service busses:
  • 601PP,
  • 602PP.
    These sub-busbars are supplied directly from the ground power unit through the contactor 14XX via the TR2.
    The contactor 14XX is controlled by the MAINT BUS control switch 5XX located on panel 2000VU.
** ON A/C NOT FOR ALL
4. Operation/Control and Indicating
The operation is described in ATA Ref. 24-42-00.
NOTE: In case of TR2 overheat, the supply of the ground service network is cut off.
[Rev.10 from 2021] 2026.04.01 05:49:20 UTC