WATER STORAGE - DESCRIPTION AND OPERATION
** ON A/C NOT FOR ALL
** ON A/C NOT FOR ALL
** ON A/C NOT FOR ALL
** ON A/C NOT FOR ALL
1. General
The potable water tank is installed in the pressurized underfloor area LH behind the rear cargo compartment. Air, which is tapped from the bleed air cross-feed line, pressurizes it (Ref. AMM 38-41-00). An indication system monitors the quantity of water in the tank (Ref. AMM 38-13-00).
The potable water tank is installed in the pressurized underfloor area RH behind the forward cargo compartment. Air, which is tapped from the bleed air cross-feed line, pressurizes it (Ref. AMM 38-41-00). An indication system monitors the quantity of water in the tank (Ref. AMM 38-13-00).
** ON A/C NOT FOR ALL The potable water tank is installed in the pressurized underfloor area LH behind the rear cargo compartment. Air, which is tapped from the bleed air cross-feed line, pressurizes it (Ref. AMM 38-41-00). An indication system monitors the quantity of water in the tank (Ref. AMM 38-13-00).
The potable water tank is installed in the pressurized underfloor area RH behind the forward cargo compartment. Air, which is tapped from the bleed air cross-feed line, pressurizes it (Ref. AMM 38-41-00). An indication system monitors the quantity of water in the tank (Ref. AMM 38-13-00).
2. Component Location
** ON A/C NOT FOR ALL | FIN | FUNCTIONAL DESIGNATION | PANEL | ZONE | ACCESS DOOR | ATA REF |
|---|---|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||||
| 3MA | TRANSMITTER,QUANTITY | 161DW | 171 | 38-13-11 | |
| ** ON A/C ALL | |||||
| 3MP | LIM SW-DRAIN HANDLE | 171 | 38-14-17 | ||
| ** ON A/C NOT FOR ALL | |||||
| 3MA | TRANSMITTER,QUANTITY | 137 | 38-13-11 | ||
| ** ON A/C NOT FOR ALL | |||||
| 3MA | TRANSMITTER,QUANTITY | 171 | 38-13-11 | ||
| ** ON A/C ALL | |||||
| 4MP | VALVE,DRAINAGE | 131HW | 133 | 38-14-41 | |
| 5MA | MSW-LIMIT SW | 171 | 38-13-16 | ||
| ** ON A/C NOT FOR ALL | |||||
| 6MA | INDICATOR,QUANTITY | 171 | 38-13-21 | ||
| ** ON A/C NOT FOR ALL | |||||
| 7MA | PRESELEC.-CONTR.-UNIT | 171 | 38-13-34 | ||
| ** ON A/C NOT FOR ALL | |||||
| 8MA | FILL/DRAIN VALVE | 161DW | 171 | 38-14-43 | |
| ** ON A/C NOT FOR ALL | |||||
| 8MP | VALVE-OVERFLOW | 132PW | 138 | 38-14-44 | |
| ** ON A/C NOT FOR ALL | |||||
| 10MA | IND-FULL | 2023VU | 171 | 38-11-00 | |
| ** ON A/C NOT FOR ALL | |||||
| 10MD | SWITCH,PRESSURE | 161DW | 171 | 38-42-16 | |
| ** ON A/C NOT FOR ALL | |||||
| 10MA | IND-FULL 1 | 171 | 38-11-00 | ||
| 14MP | VALVE-DRAIN | 132PW | 138 | 38-14-45 | |
| 16MA | FILL/DRAIN VALVE | 161DW | 171 | 38-14-46 | |
| ** ON A/C NOT FOR ALL | |||||
| 2023VU | CTL PNL-WATER QTY IND | 171 | 93-00-00 | ||
| ** ON A/C NOT FOR ALL | |||||
| 3000MM | TANK-POTABLE WATER | 161DW | 171 | 38-11-41 | |
| ** ON A/C NOT FOR ALL | |||||
| 3000MM | TANK-POTABLE WATER | 161DW | 138 | 38-11-41 | |
| ** ON A/C NOT FOR ALL | |||||
| 3000MM | TANK-POTABLE WATER | 171 | 38-11-41 | ||
| ** ON A/C ALL | |||||
| 3254MM | CONTROL CABLE,FILL/DRAIN | 161DW | 171 | 38-14-47 | |
3. System Description
A. Potable Water
(1) The potable water is kept in the water storage system.
You can fill the potable water tank with water from potable-water service panel 2023VU.
The potable-water service panel is installed in the left lower fuselage between FR65 and FR66. The panel has:
You can fill the potable water tank with water from potable-water service panel 2023VU.
The potable-water service panel is installed in the left lower fuselage between FR65 and FR66. The panel has:
- A connection for the ground air-pressure unit
- A heated fill/drain port for the potable water
- A heated overflow drain-port for the potable water
- The fill/drain and overflow control handle(s)
- Quantity indicator 6MA
- Tank full control-light 10MA
- Control light 2MP for motorized drain valve 4MP
- Limit switch drain-handle 3MP
- Limit switch 5MA.
(2) The potable Water is kept in the storage system.
You fill the potable water tank from the potable-water service panel-2023VU.
The potable-water service panel is located in the left-hand lower fuselage, between FR65 and FR66. The panel has:
When the control handle 3254MM is selected to the "DRAIN" position it operates:
Placards are installed adjacent to all the service panel connections and the fill/drain control handle to identify their operation.
You fill the potable water tank from the potable-water service panel-2023VU.
The potable-water service panel is located in the left-hand lower fuselage, between FR65 and FR66. The panel has:
- a connection for the ground air-pressure unit
- a fill/drain port for the potable water
- the fill/drain control handle
- a water quantity indicator (Ref. AMM 38-13-00)
- Control light 2MP for the motorized drain valve 4MP
- Control light 12MP for the motorized drain valve 14MP
- Control light 6MP for the motorized overflow valve 8MP
- Limit switch 5MA
- Limit switch drain-handle 3MP
- Limit switch fill-condition 5MP.
When the control handle 3254MM is selected to the "DRAIN" position it operates:
- Fill/drain valve 16MA
- Limit switch drain-handle 3MP.
- Motorized drain valve 14MP
- Motorized overflow/ventilation valve 8MP
- Motorized drain valve 4MP.
Placards are installed adjacent to all the service panel connections and the fill/drain control handle to identify their operation.
(3) The potable-Water is kept in the water storage system.
You can the potable water tank from the potable-water service panel 2023VU.
The potable-water system service-panel is located in the left-hand lower fuselage, between FR65 and FR66. The panel contains:
You can the potable water tank from the potable-water service panel 2023VU.
The potable-water system service-panel is located in the left-hand lower fuselage, between FR65 and FR66. The panel contains:
- A connection for the ground air-pressure unit
- A fill/drain port for the potable water
- An overflow drain port for the potable water
- The fill/drain and overflow control handle
- Tank full control-light 10MA
- Control light 2MP for the motorized drain valve
- Limit switch drain-handle 3MP
- Limit switch 5MA.
(4) The potable water tank is kept in the water storage system.
You can fill the potable water tank with water from potable-water service panel 2023VU.
Potable-water service panel 2023VU is installed on the left side of the lower fuselage, between FR65 and FR66. The panel has:
You can fill the potable water tank with water from potable-water service panel 2023VU.
Potable-water service panel 2023VU is installed on the left side of the lower fuselage, between FR65 and FR66. The panel has:
- A connection for the ground air-pressure unit
- A fill/drain port for the potable water
- A heated overflow drain-port for the potable water
- The fill/drain control handle
- Quantity indicator 6MA
- Tank full control-light 10MA
- Control light 2MP for motorized drain valve 4MP
- Limit switch drain-handle 3MP
- Limit switch 5MA.
4. Component Description
A. Water Tank FIN: 3000-MM
The potable water tank is installed in the pressurized underfloor area of the RH fuselage, behind the forward cargo compartment. It is made of Glassfiber Reinforced Plastic (GFRP). It is strengthened to accept the rated pressure for the potable water system of between 22 and 25 psi (1.5 and 1.72 bar). The tank has a capacity of 200 l (53 USgal).
The tank is assembled with:
The potable water tank is attached to the aircraft structure with the clamps.
The potable water tank has:
The potable water tank is installed in the pressurized underfloor area of the RH fuselage, behind the forward cargo compartment. It is made of Glassfiber Reinforced Plastic (GFRP). It is strengthened to accept the rated pressure for the potable water system of between 22 and 25 psi (1.5 and 1.72 bar). The tank has a capacity of 200 l (53 USgal).
The tank is assembled with:
- an overflow port,
- an installation port for the water-contents quantity transmitter 3MA,
- a connection for fill/drain/distribution plumbing,
- a connection for air pressurization plumbing.
The potable water tank is attached to the aircraft structure with the clamps.
The potable water tank has:
- An overflow port
- An installation port for the fill/overflow drain valve
- An installation port for water-contents quantity transmitter 3MA
- A connection for the air pressurization system with an air-no water valve.
B. Fill Valves
(1) Fill/Drain Valve 16MA
The fill/drain valve is installed below the cabin floor in Zone 171. The valve is attached to the outer left support strut at STA3158/FR66. Tube assemblies connect the valve to the potable water tank and to the potable water service-panel. The fill function of the valve also operates as a system drain facility. You can manually select the fill and drain facilities on the service panel.
The fill/drain valve is installed below the cabin floor in Zone 171. The valve is attached to the outer left support strut at STA3158/FR66. Tube assemblies connect the valve to the potable water tank and to the potable water service-panel. The fill function of the valve also operates as a system drain facility. You can manually select the fill and drain facilities on the service panel.
(2) Fill/Overflow Drain Valve 8MA:
The fill/overflow drain valve is installed between the water service panel and the potable water tank. The tube assemblies connect the valve to the tank and to the ports on the potable-water service panel. The fill function of the valve will also operate as a system drain facility. You can manually select the fill and drain facilities on the service panel. The overflow function will operate as an overflow outlet and a vent for the tank.
The fill/drain valve control-handle will open the overflow port, when it is selected to the 'FILL' or 'DRAIN' position.
The fill/overflow drain valve is installed between the water service panel and the potable water tank. The tube assemblies connect the valve to the tank and to the ports on the potable-water service panel. The fill function of the valve will also operate as a system drain facility. You can manually select the fill and drain facilities on the service panel. The overflow function will operate as an overflow outlet and a vent for the tank.
The fill/drain valve control-handle will open the overflow port, when it is selected to the 'FILL' or 'DRAIN' position.
C. Overflow Valve 8MP
The overflow valve is installed below the cabin floor in the area of the potable water tank at STA1536/FR35. The fill and drain limit switches 3MP and 5MP, which are installed on the potable water service-panel operates the valve.
The overflow valve is installed below the cabin floor in the area of the potable water tank at STA1536/FR35. The fill and drain limit switches 3MP and 5MP, which are installed on the potable water service-panel operates the valve.
5. Operation
A. Fill System (with Electrical Power)
You fill the water tank, when fill/drain valve 16MA is open. The valve opens when you turn the control handle on the potable water service-panel from "NORMAL" to "FILL" and pull the control handle out. With the control handle pulled out to its stop, fill/drain valve 16MA opens. Limit switch 5MP is energized and opens overflow/ventilation valve 8MP and control light 6MP comes on.
The maximum pressure required to fill the tank is 50 psi (3 bar).
When the tank is full, the quantity transmitter closes the fill/drain valve. The control handle is automatically pulled in and returns to the normal position. In this position, limit switch 5MP is de-energized and closes the motorized overflow/ventilation valve 8MP.
You can only fill the water tank when fill/overflow drain valve 8MA is open. The valve opens when you turn the control handle on the service panel from 'NORMAL' to 'FILL' and pull the control handle out. With the control handle pulled out to its stop, the 'fill-drain' and 'overflow' ducts open.
The maximum pressure necessary to fill the tank is 50 psi (3.4 bar). When the tank is full, the quantity transmitter closes the fill/overflow drain valve. The control handle automatically goes back to the 'NORMAL' position and the tank full control-light comes on.
When you fill the system without electrical power, there is no indication when the tank is full. The control handle will stay in the PULL TO FILL position. You must manually turn the control handle to the NORMAL position to close fill/overflow drain valve 8MA.
You fill the water tank, when fill/drain valve 16MA is open. The valve opens when you turn the control handle on the potable water service-panel from "NORMAL" to "FILL" and pull the control handle out. With the control handle pulled out to its stop, fill/drain valve 16MA opens. Limit switch 5MP is energized and opens overflow/ventilation valve 8MP and control light 6MP comes on.
The maximum pressure required to fill the tank is 50 psi (3 bar).
When the tank is full, the quantity transmitter closes the fill/drain valve. The control handle is automatically pulled in and returns to the normal position. In this position, limit switch 5MP is de-energized and closes the motorized overflow/ventilation valve 8MP.
You can only fill the water tank when fill/overflow drain valve 8MA is open. The valve opens when you turn the control handle on the service panel from 'NORMAL' to 'FILL' and pull the control handle out. With the control handle pulled out to its stop, the 'fill-drain' and 'overflow' ducts open.
The maximum pressure necessary to fill the tank is 50 psi (3.4 bar). When the tank is full, the quantity transmitter closes the fill/overflow drain valve. The control handle automatically goes back to the 'NORMAL' position and the tank full control-light comes on.
When you fill the system without electrical power, there is no indication when the tank is full. The control handle will stay in the PULL TO FILL position. You must manually turn the control handle to the NORMAL position to close fill/overflow drain valve 8MA.
A. Fill System (without Electrical Power)
You can also fill the water tank, when there is no electrical power. To do so you must open fill/drain valve 16MA and overflow valve 8MP manually.
To open fill/drain valve 16MA, you turn the control handle on the potable water service-panel from "NORMAL" to "FILL". Then pull the control handle out to its stop.
To open overflow/ventilation valve 8MP, you turn the control handle at the overflow and drain panel 192NB from "SHUT" to "OPEN".
There are no indications that the valves are open.
The maximum pressure required to fill the tank is 50 psi (3 bar).
When the tank is full, you must close the valves manually again.
You can also fill the water tank, when there is no electrical power. To do so you must open fill/drain valve 16MA and overflow valve 8MP manually.
To open fill/drain valve 16MA, you turn the control handle on the potable water service-panel from "NORMAL" to "FILL". Then pull the control handle out to its stop.
To open overflow/ventilation valve 8MP, you turn the control handle at the overflow and drain panel 192NB from "SHUT" to "OPEN".
There are no indications that the valves are open.
The maximum pressure required to fill the tank is 50 psi (3 bar).
When the tank is full, you must close the valves manually again.
Water Storage System - Component Location