W DOC AIRBUS | AMM A320F

AIR CONDITIONING DUCT AND ACCESSORY COMPARTMENT LIGHTING - DESCRIPTION AND OPERATION


** ON A/C NOT FOR ALL
1. General
The air conditioning compartment is provided with an electrical outlet for a portable maintenance light.
** ON A/C NOT FOR ALL
2. Component Location
FIN FUNCTIONAL
DESIGNATION
PANEL ZONE ACCESS
DOOR
ATA REF
** ON A/C NOT FOR ALL
2LK OUTLET-28VDC 138 33-32-00
** ON A/C NOT FOR ALL
3. System Description
The electrical outlet is supplied from the 28 V DC busbar 208PP. When the busbar is energized and the circuit breaker 1LK is closed, power is available at the maintenance outlet 2LK. The outlet is designed for use up to a maximum of 50 Watts.