ELECTRICAL SERVICE SUPPLY - DESCRIPTION AND OPERATION
** ON A/C NOT FOR ALL
** ON A/C NOT FOR ALL
1. General
The electrical service supply-system is installed to supply electrical power to sockets which you can use for electrical equipment.
** ON A/C NOT FOR ALL The electrical service supply-system is installed to supply electrical power to sockets which you can use for electrical equipment.
2. Component Location
** ON A/C NOT FOR ALL | ------------------------------------------------------------------------------- |
| FIN ! FUNCTIONAL DESIGNATION ! PANEL!ZONE!ACCESS ! ATA |
| ! ! ! ! DOOR ! REF. |
| ------------------------------------------------------------------------------- |
| 7ME WALL SOCKET 222 831 |
| 13ME WALL SOCKET 261 831 |
3. System Description
The electrical service supply-system in the passenger cabin is divided into 2 sections:
The electrical service supply-system in the passenger cabin is divided into 2 sections:
- the FWD cabin system,
- the AFT cabin system.
A. The FWD Cabin System
The FWD cabin system has a circuit breaker panel 2000VU and an electrical socket 7ME.
The FWD cabin system is connected to the circuit breaker panel 2000VU.
The circuit breaker panel 2000VU is installed on the ceiling near the FWD passenger/crew door.
The FWD cabin system has a circuit breaker panel 2000VU and an electrical socket 7ME.
The FWD cabin system is connected to the circuit breaker panel 2000VU.
The circuit breaker panel 2000VU is installed on the ceiling near the FWD passenger/crew door.
- The electrical socket 7ME is installed on the RH side of the passsenger/crew door.
B. The AFT Cabin System
The AFT cabin system has a circuit breaker panel 2001VU and an electrical socket 13ME.
The AFT cabin system is connected to the circuit breaker panel 2001VU.
The circuit breaker panel 2001VU is installed on the ceiling near the AFT passenger/crew door.
The AFT cabin system has a circuit breaker panel 2001VU and an electrical socket 13ME.
The AFT cabin system is connected to the circuit breaker panel 2001VU.
The circuit breaker panel 2001VU is installed on the ceiling near the AFT passenger/crew door.
- The electrical socket 13ME is installed on the RH side of the passsenger/crew door.
4. Power Supply
The busbar 214XP nad 212XP supply 115 V AC, 400 Hz to each wall-socket. Each wall-socket has an isolated electrical circuit and is independently protected by a 10 A circuit breaker. The circuit breakers are installed on the circuit breaker panels 2000VU and 2001VU.
The busbar 214XP nad 212XP supply 115 V AC, 400 Hz to each wall-socket. Each wall-socket has an isolated electrical circuit and is independently protected by a 10 A circuit breaker. The circuit breakers are installed on the circuit breaker panels 2000VU and 2001VU.
Sockets for Vacuum Cleaner