STATIC INVERTER - DESCRIPTION AND OPERATION
** ON A/C NOT FOR ALL
1. General
The 1000 VA nominal-power static inverter transforms the direct current voltage from battery 1 into a single-phase 115 VAC/400 Hz alternating current.
** ON A/C NOT FOR ALL The 1000 VA nominal-power static inverter transforms the direct current voltage from battery 1 into a single-phase 115 VAC/400 Hz alternating current.
2. Component Location
** ON A/C NOT FOR ALL | ------------------------------------------------------------------------------- |
| FIN ! FUNCTIONAL DESIGNATION ! PANEL!ZONE!ACCESS ! ATA |
| ! ! ! ! DOOR ! REF. |
| _______________________________________________________________________________ |
| 5XB HOLDER-FUSE 105VU 126 822 24-28-00 |
| 5XB1 FUSE-AC STAT INV BUS SPLY 105VU 126 822 24-28-00 |
| FIN | FUNCTIONAL DESIGNATION | PANEL | ZONE | ACCESS DOOR | ATA REF |
|---|---|---|---|---|---|
| ** ON A/C ALL | |||||
| 2XB | CNTOR-STAT INV | 105VU | 126 | 24-28-55 | |
| 3XB | STAT INV | 126 | 24-28-51 | ||
| 5XB | HOLDER-AC STAT INV BUS SPLY FUSE | 105VU | 126 | 24-28-00 | |
3. System Description
The static inverter starts to operate automatically in the conditions that follow:
** ON A/C NOT FOR ALL The static inverter starts to operate automatically in the conditions that follow:
- APU start (supply of fuel pump)
- Battery supplies the engine ignition system (in emergency configuration)
- Ram Air Turbine (RAT) deployment (< 10s) (supply of ECAM display units),
- On ground, on batteries only (pushbutton switch supply)
- In emergency configuration after landing, when the CSM/G is switched off (the 115 VAC ESS BUS 4XP is supplied, the CSM/G is not supplied).
4. Operation/Control and Indicating
The static inverter starts automatically if:
The presence of the ground signal means:
When the network is supplied, STATIC INV FAULT message appears on the upper ECAM display unit.
The fault indication will be available during BCL BITE reading from the Centralized Fault Display System (CFDS).
** ON A/C NOT FOR ALL The static inverter starts automatically if:
- the AC BUS 1 and 2 are lost,
- the CSM/G is not available, and
- speed is more than 50 Kts.
The presence of the ground signal means:
- overheat,
- output overvoltage,
- input undervoltage,
- input overvoltage.
When the network is supplied, STATIC INV FAULT message appears on the upper ECAM display unit.
The fault indication will be available during BCL BITE reading from the Centralized Fault Display System (CFDS).
5. Test
On the ground, the static inverter can be checked applying the following procedure (aircraft supplied by EXT POWER or APU GEN):
On the ground, the static inverter can be checked applying the following procedure (aircraft supplied by EXT POWER or APU GEN):
- EMER GEN TEST: ON
- BUS TIE: OFF
- On the ECAM ELEC page, check voltage and frequency of static inverter.
Contactor and Fuse - Component Location