STATIC INVERTER - DESCRIPTION AND OPERATION


** ON A/C NOT FOR ALL
1. General
The 1000 VA nominal-power static inverter transforms the direct current voltage from battery 1 into a single-phase 115 VAC/400 Hz alternating current.
** ON A/C NOT FOR ALL
2. Component Location
-------------------------------------------------------------------------------
FIN ! FUNCTIONAL DESIGNATION ! PANEL!ZONE!ACCESS ! ATA
! ! ! ! DOOR ! REF.
_______________________________________________________________________________
5XB HOLDER-FUSE 105VU 126 822 24-28-00
5XB1 FUSE-AC STAT INV BUS SPLY 105VU 126 822 24-28-00

FIN FUNCTIONAL
DESIGNATION
PANEL ZONE ACCESS
DOOR
ATA REF
** ON A/C ALL
2XB CNTOR-STAT INV 105VU 126 24-28-55
3XB STAT INV 126 24-28-51
5XB HOLDER-AC STAT INV BUS SPLY FUSE 105VU 126 24-28-00
** ON A/C NOT FOR ALL
3. System Description
The static inverter starts to operate automatically in the conditions that follow:
  • APU start (supply of fuel pump)
  • Battery supplies the engine ignition system (in emergency configuration)
  • Ram Air Turbine (RAT) deployment (< 10s) (supply of ECAM display units),
  • On ground, on batteries only (pushbutton switch supply)
  • In emergency configuration after landing, when the CSM/G is switched off (the 115 VAC ESS BUS 4XP is supplied, the CSM/G is not supplied).
** ON A/C NOT FOR ALL
4. Operation/Control and Indicating
The static inverter starts automatically if:
  • the AC BUS 1 and 2 are lost,
  • the CSM/G is not available, and
  • speed is more than 50 Kts.
When the static inverter is faulty, it generates a permanent ground signal to the BCL1.
The presence of the ground signal means:
  • overheat,
  • output overvoltage,
  • input undervoltage,
  • input overvoltage.
The static inverter defect is sent to the battery charge limiter 1 which stores it in a memory as a class I failure.
When the network is supplied, STATIC INV FAULT message appears on the upper ECAM display unit.
The fault indication will be available during BCL BITE reading from the Centralized Fault Display System (CFDS).
** ON A/C NOT FOR ALL
5. Test
On the ground, the static inverter can be checked applying the following procedure (aircraft supplied by EXT POWER or APU GEN):
  • EMER GEN TEST: ON
  • BUS TIE: OFF
  • On the ECAM ELEC page, check voltage and frequency of static inverter.